{"title":"Modules \u0026 Relays","description":"\u003cp\u003eAddressable monitor, control, relay, and isolator modules from Notifier, Edwards, Fire-Lite, Simplex, Gamewell-FCI, and other leading brands. Input, output, zone interface, releasing, and multi-voltage relay modules for commercial fire alarm systems.\u003c\/p\u003e","products":[{"product_id":"fire-lite-mmf-301-mini-addressable-monitor-module","title":"Fire-Lite MMF-301 Mini Addressable Monitor Module","description":"\u003ch3\u003eFire-Lite MMF-301 Intelligent Monitor Module\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFire-Lite MMF-301 Intelligent Monitor Module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edelivers dependable and efficient supervision of dry contact devices within addressable fire alarm systems. This device enhances fire safety through precise monitoring and seamless communication with compatible Fire-Lite panels. Its compact design and easy installation make it ideal for a variety of commercial and industrial applications.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003ch4\u003eAddressable Supervision for Precise Detection\u003c\/h4\u003e\n\u003cp\u003eThe Fire-Lite MMF-301 Intelligent Monitor Module monitors a single Class B circuit and reports the status of connected devices—such as pull stations or waterflow switches—directly to the fire alarm control panel. As a result, it provides fast and accurate zone identification, improving emergency response.\u003c\/p\u003e\n\u003ch4\u003eCompact and Flexible Design for Versatile Installation\u003c\/h4\u003e\n\u003cp\u003eDue to its small size, the module fits easily inside a single-gang electrical box, offering convenient placement in confined spaces. Additionally, its low-profile form factor is perfect for both retrofit and new construction projects, ensuring a flexible solution for installers.\u003c\/p\u003e\n\u003ch4\u003eEase of Installation and Maintenance\u003c\/h4\u003e\n\u003cp\u003eThe MMF-301 features a terminal block for secure, efficient wiring. Moreover, the built-in LED indicator provides instant visual confirmation of device status, which simplifies diagnostics and system checks during maintenance.\u003c\/p\u003e\n\u003ch3\u003eReliable Communication and Compliance\u003c\/h3\u003e\n\u003ch4\u003eTwo-Wire SLC Integration\u003c\/h4\u003e\n\u003cp\u003eConnecting via the Signaling Line Circuit (SLC), the module utilizes reliable two-wire communication with the control panel. Therefore, it ensures fast and consistent signal transmission without complex wiring requirements.\u003c\/p\u003e\n\u003ch4\u003eBroad Compatibility and Standards Compliance\u003c\/h4\u003e\n\u003cp\u003eFully compatible with Fire-Lite addressable fire alarm control panels, this module meets key industry standards, including UL 864. Consequently, it is suitable for systems that demand trustworthy supervision of various dry contact devices.\u003c\/p\u003e\n\u003ch3\u003eApplication and Use\u003c\/h3\u003e\n\u003cp\u003eThe Fire-Lite MMF-301 Intelligent Monitor Module is designed for environments where individual device monitoring is critical. Common uses include manual pull stations, waterflow detectors, and other initiating devices that require individual supervision. Its design supports dependable integration into systems for commercial buildings, educational institutions, and healthcare facilities.\u003c\/p\u003e\n\u003ch3\u003eAdvantages\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnhanced Monitoring\u003c\/strong\u003e: Delivers real-time updates for supervised devices, improving system responsiveness.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSpace-Saving Design\u003c\/strong\u003e: Compact size ensures easy installation in limited spaces.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLow Maintenance\u003c\/strong\u003e: LED indicator streamlines troubleshooting and regular system checks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeamless Compatibility\u003c\/strong\u003e: Works efficiently with Fire-Lite addressable systems for versatile use cases.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"FIRE-LITE","offers":[{"title":"Default Title","offer_id":54014021304627,"sku":"MMF-301","price":43.95,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1000\/9785\/1699\/files\/fire-lite-mmf-301-mini-addressable-monitor-module-plena-v2.jpg?v=1795214162"},{"product_id":"notifier-frm-1-addressable-relay-module-dpdt","title":"Notifier FRM-1 Addressable Relay Module, DPDT","description":"\u003cp class=\"isSelectedEnd\"\u003eThe \u003cstrong\u003eNotifier FRM-1\u003c\/strong\u003e is a commercial addressable relay module designed for compatible Notifier intelligent fire alarm control panels. It provides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003etwo isolated Form-C dry contacts (DPDT)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor controlling auxiliary equipment such as HVAC systems, door holders, smoke dampers, elevators, fans, and other building control devices.\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003ePowered directly from the Signaling Line Circuit (SLC), the FRM-1 features FlashScan® and CLIP® communication compatibility, rotary decimal addressing, and an integral status LED for dependable operation and simplified installation. This product is intended exclusively for commercial fire alarm installations.\u003c\/p\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch3\u003eProduct Functions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eControls auxiliary building equipment\u003c\/li\u003e\n\u003cli\u003eProvides two isolated Form-C dry contacts\u003c\/li\u003e\n\u003cli\u003eSupports HVAC shutdown\u003c\/li\u003e\n\u003cli\u003eControls smoke dampers\u003c\/li\u003e\n\u003cli\u003eControls door holders\u003c\/li\u003e\n\u003cli\u003eSupports elevator interface functions\u003c\/li\u003e\n\u003cli\u003eResets compatible four-wire smoke detector power\u003c\/li\u003e\n\u003cli\u003eProvides continuous SLC communication and supervision\u003c\/li\u003e\n\u003cli\u003eIndividual address identification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch3\u003eElectrical \u0026amp; System Information\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003eThe FRM-1 operates directly from a compatible\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e15–32 VDC Signaling Line Circuit (SLC)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand requires no separate operating power for module electronics or relay operation. The module occupies a single SLC address while both Form-C relay outputs operate simultaneously as a DPDT relay.\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003eTwo rotary decimal switches provide local addressing, while the integral LED flashes green during normal polling and illuminates steadily when the relay is activated. Circuit connections to the relay contacts are not supervised by the module.\u003c\/p\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCommercial addressable relay module\u003c\/li\u003e\n\u003cli\u003eTwo isolated Form-C dry contacts\u003c\/li\u003e\n\u003cli\u003eDPDT relay operation\u003c\/li\u003e\n\u003cli\u003eFlashScan® and CLIP® compatible\u003c\/li\u003e\n\u003cli\u003ePowered directly from the SLC\u003c\/li\u003e\n\u003cli\u003eRotary decimal addressing\u003c\/li\u003e\n\u003cli\u003eIntegral green\/red status LED\u003c\/li\u003e\n\u003cli\u003eAutomatic device identification\u003c\/li\u003e\n\u003cli\u003eHigh EMI\/RFI immunity\u003c\/li\u003e\n\u003cli\u003eSEMS screw terminals\u003c\/li\u003e\n\u003cli\u003eLow standby current\u003c\/li\u003e\n\u003cli\u003eCompact mounting design\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch3\u003eMounting \u0026amp; Design\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003eThe FRM-1 mounts directly to a standard\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e4-inch square electrical box\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewith a minimum depth of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e2⅛ inches (54 mm)\u003c\/strong\u003e. An optional\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSMB500 surface-mount back box\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis available for surface installations.\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003eIts off-white heat-resistant enclosure includes front-access rotary address switches and SEMS screw terminals that simplify installation, programming, and servicing. The module may also be installed in compatible DNR(DNRW) duct detector housings where supported.\u003c\/p\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch3\u003eProtection \u0026amp; Applications\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003eSuitable for:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHVAC Shutdown\u003c\/li\u003e\n\u003cli\u003eDoor Holder Release\u003c\/li\u003e\n\u003cli\u003eSmoke Dampers\u003c\/li\u003e\n\u003cli\u003eExhaust Fans\u003c\/li\u003e\n\u003cli\u003eElevator Interface\u003c\/li\u003e\n\u003cli\u003eBuilding Automation Equipment\u003c\/li\u003e\n\u003cli\u003eFour-Wire Detector Power Reset\u003c\/li\u003e\n\u003cli\u003eCommercial Fire Alarm Systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003eCompatible with:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNotifier ONYX® Fire Alarm Control Panels\u003c\/li\u003e\n\u003cli\u003eFlashScan® Signaling Line Circuits\u003c\/li\u003e\n\u003cli\u003eCLIP® Signaling Line Circuits\u003c\/li\u003e\n\u003cli\u003eNFS2-640 Fire Alarm Control Panel\u003c\/li\u003e\n\u003cli\u003eNFS2-3030 Fire Alarm Control Panel\u003c\/li\u003e\n\u003cli\u003eAFP Series Fire Alarm Control Panels\u003c\/li\u003e\n\u003cli\u003eSMB500 Surface-Mount Back Box\u003c\/li\u003e\n\u003cli\u003eCompatible Auxiliary Equipment with Dry-Contact Inputs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003eAlways verify compatibility with the installed fire alarm control panel, SLC protocol, firmware version, controlled equipment, and project requirements before installation.\u003c\/p\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNotifier\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003eParent Company:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHoneywell\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFRM-1\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAddressable Relay Module\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003eRelay Configuration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTwo Isolated Form-C Dry Contacts (DPDT)\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003eCommunication Protocol:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFlashScan® and CLIP®\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003eOperating Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e15–32 VDC\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003ePower Source:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSignaling Line Circuit (SLC)\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003eAverage Operating Current:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e350 µA (Direct Poll)\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003eAverage Operating Current:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e375 µA (Group Poll with LED Flashing)\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003eMaximum Current Draw:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e6.5 mA (LED On)\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003eAddressing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRotary Decimal Switches\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003eAddress Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e01–159 (FlashScan®), 01–99 (CLIP®)\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003eStatus Indicator:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eGreen\/Red LED\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard 4-Inch Square Electrical Box\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIndoor Commercial Fire Alarm Systems\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003eListings:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUL Listed, ULC Listed, FM Approved, CSFM Listed, and MEA Approved (application dependent). Verify product labeling and project requirements before installation.\u003c\/p\u003e","brand":"NOTIFIER","offers":[{"title":"Default Title","offer_id":54014021435699,"sku":"FRM-1","price":68.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1000\/9785\/1699\/files\/notifier-frm-1-addressable-relay-module-dpdt-plena-v2.jpg?v=1795214162"},{"product_id":"fire-lite-crf-300-addressable-control-relay-module","title":"Fire-Lite CRF-300 Addressable Control Module with DPDT Relay","description":"\u003ch3 class=\"\"\u003eFireLite CRF-300 Relay Control Module: Reliable Addressable Output Control\u003c\/h3\u003e\n\u003cp class=\"\"\u003eThe FireLite CRF-300 is a compact and dependable relay control module. It is designed to activate external devices based on signals from a fire alarm control panel. This unit enhances fire protection systems in commercial and institutional buildings.\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eKey Features\u003c\/h3\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eAddressable Operation\u003c\/strong\u003e\u003cbr\u003eThe CRF-300 works with FireLite addressable panels, allowing two-way communication. As a result, it ensures precise and reliable control of output devices.\u003c\/p\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eForm C Relay Output\u003c\/strong\u003e\u003cbr\u003eThis module includes a Form C (SPDT) relay. It supports both normally open and normally closed circuits, offering flexibility for a wide range of applications.\u003c\/p\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eStatus Indication\u003c\/strong\u003e\u003cbr\u003eIt features dual LEDs that show activation and communication status. Therefore, it helps with quick diagnostics and easier maintenance.\u003c\/p\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eIsolated Mounting\u003c\/strong\u003e\u003cbr\u003eThe CRF-300 mounts directly into standard electrical boxes. This makes installation simpler and helps organize wiring in compact spaces.\u003c\/p\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eUL-Listed and NFPA Compliant\u003c\/strong\u003e\u003cbr\u003eIt complies with UL safety standards and follows NFPA 72 code requirements. This ensures it meets the highest fire safety regulations.\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eApplication and Usage\u003c\/h3\u003e\n\u003cp class=\"\"\u003eThe FireLite CRF-300 is ideal for controlling auxiliary devices during emergencies. For example, it can be used for elevator recall, fan shutdown, smoke control, and door holder release. Its addressable design is perfect for large systems that need individual device control.\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eInstallation Tips\u003c\/h3\u003e\n\u003cp class=\"\"\u003eInstall the CRF-300 close to the equipment it controls. This minimizes wiring and improves accessibility. Also, follow the manufacturer’s wiring diagrams and test the module after installation to confirm proper function.\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eAdvantages\u003c\/h3\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eFlexible Control\u003c\/strong\u003e: Operates a variety of external devices using Form C relay contacts\u003cbr\u003e\u003cstrong\u003eSmooth Integration\u003c\/strong\u003e: Easily connects with FireLite addressable systems\u003cbr\u003e\u003cstrong\u003eCompact and Practical\u003c\/strong\u003e: Fits into standard boxes and saves space\u003cbr\u003e\u003cstrong\u003eClear Feedback\u003c\/strong\u003e: LEDs provide visual status for quick troubleshooting\u003cbr\u003e\u003cstrong\u003eStandards-Compliant\u003c\/strong\u003e: Meets UL and NFPA requirements for fire safety systems\u003c\/p\u003e","brand":"FIRE-LITE","offers":[{"title":"Default Title","offer_id":54014021501235,"sku":"CRF-300","price":69.99,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1000\/9785\/1699\/files\/fire-lite-crf-300-addressable-control-relay-module-plena-v2.webp?v=1795214031"},{"product_id":"notifier-fmm-101-mini-addressable-monitor-module","title":"Notifier FMM-101 Mini Addressable Monitor Module","description":"\u003cp class=\"isSelectedEnd\"\u003eThe \u003cstrong\u003eNotifier FMM-101\u003c\/strong\u003e is a compact addressable mini monitor module designed for compatible Notifier intelligent fire alarm control panels. It provides an addressable interface for monitoring normally open dry-contact initiating devices, allowing conventional initiating devices to communicate over the Signaling Line Circuit (SLC).\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003eIts miniature design allows installation inside a standard single-gang electrical box directly behind the monitored device, making it ideal for retrofit projects and installations with limited mounting space. This product is intended exclusively for commercial fire alarm installations.\u003c\/p\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch3\u003eProduct Functions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMonitors normally open dry-contact devices\u003c\/li\u003e\n\u003cli\u003eProvides a supervised Class B (Style B) initiating device circuit\u003c\/li\u003e\n\u003cli\u003eReports alarm and supervisory conditions to the control panel\u003c\/li\u003e\n\u003cli\u003eSupervises initiating device wiring\u003c\/li\u003e\n\u003cli\u003eSupports individual address identification\u003c\/li\u003e\n\u003cli\u003eMonitors manual pull stations, waterflow switches, tamper switches, pressure switches, and other compatible dry-contact devices\u003c\/li\u003e\n\u003cli\u003eContinuous communication with the SLC loop\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch3\u003eElectrical \u0026amp; System Information\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003eThe FMM-101 operates directly from the compatible Notifier\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e15–32 VDC Signaling Line Circuit (SLC)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand requires no separate operating power supply. Address selection is accomplished using built-in rotary decimal switches.\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003eThe initiating device circuit is supervised with the supplied\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e47 kΩ end-of-line resistor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand supports a maximum wiring resistance of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1,500 Ω\u003c\/strong\u003e. The compact module is intended for concealed installation inside a standard single-gang electrical box.\u003c\/p\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCommercial addressable mini monitor module\u003c\/li\u003e\n\u003cli\u003eCompact concealed design\u003c\/li\u003e\n\u003cli\u003eClass B (Style B) initiating device circuit\u003c\/li\u003e\n\u003cli\u003eRotary decimal addressing\u003c\/li\u003e\n\u003cli\u003ePanel-powered operation\u003c\/li\u003e\n\u003cli\u003eNo external operating power required\u003c\/li\u003e\n\u003cli\u003eBuilt-in status LED\u003c\/li\u003e\n\u003cli\u003eHigh EMF\/RFI immunity\u003c\/li\u003e\n\u003cli\u003e47 kΩ end-of-line resistor included\u003c\/li\u003e\n\u003cli\u003eIdeal for retrofit installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch3\u003eMounting \u0026amp; Design\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003eThe FMM-101 is designed for installation inside a standard single-gang electrical box behind the monitored device. Its lightweight construction allows installation without rigid mounting hardware, making it well suited for confined spaces and retrofit applications.\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003eThe module includes factory-installed wire leads for simple field wiring and concealed installation.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNotifier\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003eParent Company:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHoneywell\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFMM-101\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAddressable Mini Monitor Module\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003eCircuit Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eClass B (Style B) Initiating Device Circuit\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003eOperating Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e15–32 VDC\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003ePower Source:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSignaling Line Circuit (SLC)\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003eAverage Operating Current:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e350 µA\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003eEnd-of-Line Resistor:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e47 kΩ (Included)\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003eAddressing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRotary Decimal Switches\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003eAddress Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e01–159 (FlashScan), 01–99 (CLIP)\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003eStatus Indicator:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePanel-Controlled LED\u003c\/p\u003e","brand":"NOTIFIER","offers":[{"title":"Default Title","offer_id":54014021632307,"sku":"FMM-101","price":46.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1000\/9785\/1699\/files\/notifier-fmm-101-mini-addressable-monitor-module-plena-v2.jpg?v=1795214162"},{"product_id":"edwards-3-idc-8-4","title":"EDWARDS 3-IDC-8\/4 Traditional Zone I\/O Module","description":"\u003cp\u003eThe \u003cstrong\u003eEdwards 3-IDC8\/4\u003c\/strong\u003e is an EST3 traditional zone I\/O module that provides eight Class B direct-connect initiating device circuits for two-wire smoke detectors and dry-contact devices. Four of the circuits can be converted to Class B notification appliance circuits, which makes it ideal for retrofits that reuse existing wiring, detectors and signals.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e8 Class B IDCs: 4 dedicated, 4 configurable as IDCs or NACs\u003c\/li\u003e\n\u003cli\u003eIDCs set for latching or non-latching and verified or unverified smoke operation in software\u003c\/li\u003e\n\u003cli\u003eNAC pairs can be powered from the rail, an external 24 VDC supply, or pass audio\/telephone signals\u003c\/li\u003e\n\u003cli\u003eNACs rated 3.5 A at 24 VDC per pair; audio up to 70 VRMS\u003c\/li\u003e\n\u003cli\u003e4.7 kΩ EOL on initiating circuits\u003c\/li\u003e\n\u003cli\u003eStandby 48 mA, alarm 408 mA at 24 VDC\u003c\/li\u003e\n\u003cli\u003eOccupies one local rail space; UL 864 and ULC-S527 listed\u003c\/li\u003e\n\u003cli\u003eManufacturer: Edwards | Part Number: 3-IDC-8\/4 | Condition: New\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eEdwards EST3 and EST3X control panels. See the EST3\/EST3X compatibility lists for approved two-wire detectors.\u003c\/p\u003e","brand":"EDWARDS","offers":[{"title":"Default Title","offer_id":54082200240435,"sku":"3-IDC-8\/4","price":519.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1000\/9785\/1699\/files\/edwards-3-idc-8-4-plena-v2.png?v=1795214165"},{"product_id":"edwards-4-comrel","title":"EDWARDS 4-COMREL Common Relay Module","description":"\u003cp\u003eThe \u003cstrong\u003eEdwards 4-COMREL\u003c\/strong\u003e is an optional EST4 common relay card that mounts to the back of the 4-CPU and provides common alarm, common trouble and common supervisory relay outputs.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eForm C common alarm, trouble and supervisory relays\u003c\/li\u003e\n\u003cli\u003eContacts rated 30 VDC at 1 A\u003c\/li\u003e\n\u003cli\u003eMounts to the back of the 4-CPU\u003c\/li\u003e\n\u003cli\u003eConnections for end-of-line resistors; 18 to 12 AWG wire\u003c\/li\u003e\n\u003cli\u003eManufacturer: Edwards | Part Number: 4-COMREL | Condition: New\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eEdwards EST4 control units with 4-CPU.\u003c\/p\u003e","brand":"EDWARDS","offers":[{"title":"Default Title","offer_id":54082201485619,"sku":"4-COMREL","price":139.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1000\/9785\/1699\/files\/edwards-4-comrel-plena-v2.png?v=1795214279"},{"product_id":"edwards-4-fwal3","title":"EDWARDS 4-FWAL3 Network Firewall Module","description":"\u003cp\u003eThe \u003cstrong\u003eEdwards 4-FWAL3\u003c\/strong\u003e is an EST4 4-FWAL series firewall module that separates the life safety network from outside IP networks, blocking unauthorized access while permitting outward communication.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFire-listed firewall for the EST4 life safety network\u003c\/li\u003e\n\u003cli\u003eBlocks unauthorized inbound access, permits outward communication\u003c\/li\u003e\n\u003cli\u003eSupports up to 8 third-party connections and up to 2 printers\u003c\/li\u003e\n\u003cli\u003eModel 3 in the 4-FWAL series; supplier lists it as a firewall with email and secure connection support\u003c\/li\u003e\n\u003cli\u003eManufacturer: Edwards | Part Number: 4-FWAL3 | Condition: New\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eEdwards EST4 systems. Mounts with a 4-BRKT-CB or 4-BRKT-CS bracket. Compare 4-FWAL-1 through 4-FWAL-4 in the EST4 Network Firewalls data sheet to confirm the feature set you need.\u003c\/p\u003e","brand":"EDWARDS","offers":[{"title":"Default Title","offer_id":54082201714995,"sku":"4-FWAL3","price":1185.55,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1000\/9785\/1699\/files\/edwards-4-fwal3-plena-v2.png?v=1795214279"},{"product_id":"edwards-gsa-cc1","title":"EDWARDS GSA-CC1 Dual Input Signal Module","description":"\u003cp\u003e\u003cstrong\u003eGSA-CC1\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSingle Input Signal Modules and GSA-CC2\/ MCC2 Dual Input Signal Modules are Signature system. Intelligent analog addressable devices used for connecting, upon command from the loop controller, supervised Class B signal. Or telephone circuits to their respective power inputs. The power inputs polarized 24 Vdc to operate audible and visible signal appliances. Or 25 and 70 VRMS; to operate audio evacuation speakers and firefighter’s telephones.\u003c\/p\u003e\n\u003cp\u003eThe actual operation of the GSA-CC1\/MCC1 and GSA-CC2\/ MCC2 i s determined by the “personality code” selected by the installer. It w as downloaded to the module from the Signature loop controller during system configuration.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"EDWARDS","offers":[{"title":"Default Title","offer_id":54082206957875,"sku":"GSA-CC1","price":48.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1000\/9785\/1699\/files\/edwards-gsa-cc1-plena-v2.png?v=1795214281"},{"product_id":"edwards-gsa-cr","title":"EDWARDS GSA-CR Control Relay Module","description":"\u003cp\u003e\u003cstrong\u003eGSA-CR Control Relay Module\u003c\/strong\u003e\u003cspan\u003e offers dependable and flexible output control for a wide range of fire alarm applications. Designed to interface seamlessly with Vigilant addressable systems, it provides a means of activating external devices such as fans, doors, dampers, or notification appliances in response to system commands or specific programming logic.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eAdvantages\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli class=\"\"\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eReliable Output Control\u003c\/strong\u003e: Accurately triggers connected devices in fire alarm scenarios\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\"\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eSeamless Integration\u003c\/strong\u003e: Works efficiently with Vigilant addressable systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\"\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eEasy Monitoring\u003c\/strong\u003e: Built-in LED provides real-time status updates\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\"\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eCompact and Versatile\u003c\/strong\u003e: Fits easily into tight spaces and a variety of mounting options\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\"\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eSupports Safety Protocols\u003c\/strong\u003e: Helps fulfill critical response requirements for fire systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"EDWARDS","offers":[{"title":"Default Title","offer_id":54082207088947,"sku":"GSA-CR","price":53.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1000\/9785\/1699\/files\/edwards-gsa-cr-plena-v2.webp?v=1795214281"},{"product_id":"edwards-gsa-wtm","title":"EDWARDS GSA-WTM Tamper Module","description":"\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003eEdwards GSA-WTM Waterflow\/Tamper Module\u003c\/strong\u003e\u003cspan\u003e is a critical component for fire alarm systems, designed to provide accurate waterflow and tamper detection. By integrating seamlessly with Edwards’ Signature Series panels, the \u003c\/span\u003e\u003cstrong\u003eEdwards GSA-WTM\u003c\/strong\u003e\u003cspan\u003e ensures timely alerts for potential fire hazards, enhancing the safety of commercial and industrial facilities. This module is essential for facilities that need reliable monitoring of sprinkler systems and security tamper switches.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications and Compatibility\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe \u003cstrong\u003eEdwards GSA-WTM\u003c\/strong\u003e mounts easily in standard 2-1\/2″ deep 1-gang boxes or 4″ square boxes. It supports wire gauges 12–18 AWG and operates within a temperature range of 32°F to 120°F (0°C to 49°C). This module meets UL and ULC standards for fire alarm devices, ensuring compliance with industry regulations.\u003c\/p\u003e","brand":"EDWARDS","offers":[{"title":"Default Title","offer_id":54082207187251,"sku":"GSA-WTM","price":84.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1000\/9785\/1699\/files\/edwards-gsa-wtm-plena-v2.webp?v=1795214281"},{"product_id":"edwards-mr201-c","title":"EDWARDS MR201\/C Multi-Voltage Control Relay","description":"\u003cp\u003eThe \u003cstrong\u003eEdwards MR201\/C\u003c\/strong\u003e is an MR-200 Series multi-voltage control relay with a 10 A DPDT contact, mounted in an enclosure. It can be energized from 24 VDC, 24 VAC, 120 VAC or 230 VAC.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOne relay position with DPDT (2 Form C) 10 A resistive contacts\u003c\/li\u003e\n\u003cli\u003eCoil input 24 VDC\/VAC, 120 VAC or 230 VAC\u003c\/li\u003e\n\u003cli\u003eRed LED shows coil energized\u003c\/li\u003e\n\u003cli\u003eMounted in a dust-resistant enclosure with LED viewing port\u003c\/li\u003e\n\u003cli\u003eUL listed control unit accessory; CSFM listed, MEA accepted\u003c\/li\u003e\n\u003cli\u003eManufacturer: Edwards | Part Number: MR201\/C | Condition: New\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eFire alarm, HVAC, security, energy management and lighting control interlocks.\u003c\/p\u003e","brand":"EDWARDS","offers":[{"title":"Default Title","offer_id":54082208432435,"sku":"MR201\/C","price":34.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1000\/9785\/1699\/files\/edwards-mr201-c-plena-v2.png?v=1795214282"},{"product_id":"edwards-rela-eol","title":"EDWARDS RELA-EOL Polarized End-of-Line Relay","description":"\u003cp\u003eThe \u003cstrong\u003eEdwards RELA-EOL\u003c\/strong\u003e is a polarized end-of-line relay that allows non-polarized solenoids to be supervised on the release circuits of the SIGA-REL releasing module.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePolarizing end-of-line relay for release circuit supervision\u003c\/li\u003e\n\u003cli\u003eUse with the SIGA-REL releasing module\u003c\/li\u003e\n\u003cli\u003eUp to four RELA-EOLs per release circuit\u003c\/li\u003e\n\u003cli\u003eInstall in conduit within 20 ft of the solenoid\u003c\/li\u003e\n\u003cli\u003eManufacturer: Edwards | Part Number: RELA-EOL | Condition: New\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eEdwards SIGA-REL releasing modules in agent release and pre-action systems. Refer to the RELA-EOL installation sheet.\u003c\/p\u003e","brand":"EDWARDS","offers":[{"title":"Default Title","offer_id":54082208661811,"sku":"RELA-EOL","price":93.89,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1000\/9785\/1699\/files\/edwards-rela-eol-plena-v2.png?v=1795214282"},{"product_id":"edwards-siga-cc1","title":"EDWARDS SIGA-CC1 Intelligent Signal Module","description":"\u003cp\u003eThe \u003cstrong\u003eEdwards EST SIGA-CC1\u003c\/strong\u003e is an intelligent addressable signal module designed for use with Edwards Signature Series fire alarm systems. It allows the fire alarm control panel to connect and control supervised Class B signal circuits used for notification appliances, audio evacuation speakers, or firefighter telephone circuits.\u003c\/p\u003e\n\u003cp\u003eThe module operates under command of the Signature loop controller and can switch power inputs to controlled circuits depending on its programmed personality code. It supports multiple applications including audible\/visual notification power selection, audio evacuation, and telephone circuits with ring-tone generation.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eSIGA-CC1\u003c\/strong\u003e features built-in intelligence and microprocessor-based operation, enabling faster system response and improved reliability. Signature Series devices automatically report their location on the loop using automatic device mapping, simplifying system commissioning and maintenance. Electronic addressing is performed directly by the loop controller without manual switches or dials.\u003c\/p\u003e","brand":"EDWARDS","offers":[{"title":"Default Title","offer_id":54082209448243,"sku":"SIGA-CC1","price":75.25,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1000\/9785\/1699\/files\/edwards-siga-cc1-plena-v2.jpg?v=1795214283"},{"product_id":"edwards-siga-cc1s","title":"EDWARDS SIGA-CC1S Intelligent Output Module","description":"\u003cp\u003eThis \u003cstrong\u003eintelligent addressable output module\u003c\/strong\u003e provides UL 1971-compliant synchronization for visual notification appliances across multiple zones on Edwards Signature loop systems. It is part of the Signature Series and its operation is determined by a downloadable personality code: Code 25 for visual signal synchronization, Code 5 for signal power or audio evacuation riser selection, or Code 6 for telephone circuits with a built-in ring-tone generator.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eSIGA-CC1S\u003c\/strong\u003e connects a supervised Class B output circuit to a supervised 24 VDC riser input for audible\/visible signals, or to 25 and 70 VRMS inputs for audio evacuation speakers and firefighter telephones. It monitors the output wiring for open and short circuits, a short causes the panel to inhibit activation to prevent connection to the fault. Addresses are electronically programmed from the loop controller or the SIGA-PRO service tool; no switches or dials are required.\u003c\/p\u003e\n\u003cp\u003eThe module mounts to a standard North American 2-gang box (2½\" deep) or a 4\" square box (1½\" deep) with 2-gang cover and SIGA-MP mounting plate. It is compatible with EST3, EST3X, and iO Series control panels under Signature Loop Controller version 2.0 or higher.\u003c\/p\u003e","brand":"EDWARDS","offers":[{"title":"Default Title","offer_id":54082209579315,"sku":"SIGA-CC1S","price":89.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1000\/9785\/1699\/files\/edwards-siga-cc1s-plena-v2.webp?v=1795214283"},{"product_id":"edwards-siga-cc2","title":"EDWARDS SIGA-CC2 Dual Module","description":"\u003cp\u003eThe \u003cstrong\u003eEdwards SIGA-CC2 Dual Module\u003c\/strong\u003e offers flexible control for fire alarm systems by managing two independent Class B output circuits. It allows each circuit to operate separately, supporting strobes, horns, or other notification appliances. This dual capability makes it a space-saving and cost-effective solution for fire protection in commercial, industrial, and institutional buildings.\u003c\/p\u003e\n\u003ch3\u003eIndependent Dual-Circuit Functionality\u003c\/h3\u003e\n\u003cp\u003eWith two fully controllable outputs, the \u003cstrong\u003eEdwards SIGA-CC2 Dual Module\u003c\/strong\u003e enhances system efficiency. Each circuit operates under its program, allowing distinct logic and supervision. This feature simplifies system design and reduces the total number of modules required. As a result, installers can minimize wiring and maximize available panel space.\u003c\/p\u003e\n\u003ch3\u003eSeamless Edwards System Integration\u003c\/h3\u003e\n\u003cp\u003eThe SIGA-CC2 works with Edwards Signature Series control panels, using the Signature loop for communication. Its onboard microprocessor automatically identifies the module to the system, removing the need for dipswitches or manual configuration. This intelligent interface speeds up installation and ensures accurate performance across the entire alarm network.\u003c\/p\u003e","brand":"EDWARDS","offers":[{"title":"Default Title","offer_id":54082209677619,"sku":"SIGA-CC2","price":84.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1000\/9785\/1699\/files\/edwards-siga-cc2-plena-v2.webp?v=1795214283"},{"product_id":"edwards-siga-cr","title":"EDWARDS SIGA-CR Control Relay Module","description":"\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong\u003eEdwards SIGA-CR Control Relay Module\u003c\/strong\u003e is an intelligent addressable output module designed for compatible Edwards Signature Series fire alarm systems. It provides a \u003cstrong\u003eForm C dry relay contact\u003c\/strong\u003e that allows the fire alarm system to control auxiliary equipment through programmed system logic.\u003c\/p\u003e\n\u003cp\u003eThe SIGA-CR incorporates an onboard microprocessor, electronic addressing, automatic device mapping, non-volatile memory, and diagnostic status LEDs. It is commonly used where an addressable dry-contact relay output is required.\u003c\/p\u003e\n\u003ch3\u003eProduct Functions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProvides intelligent addressable relay control\u003c\/li\u003e\n\u003cli\u003eProvides one Form C dry relay contact\u003c\/li\u003e\n\u003cli\u003eSupports normally open and normally closed connections\u003c\/li\u003e\n\u003cli\u003eUses one Signature address\u003c\/li\u003e\n\u003cli\u003eProvides electronic addressing\u003c\/li\u003e\n\u003cli\u003eSupports automatic device mapping\u003c\/li\u003e\n\u003cli\u003eUses onboard microprocessor processing\u003c\/li\u003e\n\u003cli\u003eStores device information in non-volatile memory\u003c\/li\u003e\n\u003cli\u003eProvides green and red status LEDs\u003c\/li\u003e\n\u003cli\u003eSupports programmable control functions\u003c\/li\u003e\n\u003cli\u003eProvides dry-contact switching\u003c\/li\u003e\n\u003cli\u003eDesigned for compatible Edwards Signature systems\u003c\/li\u003e\n\u003cli\u003e\n\u003ch3\u003eElectrical \u0026amp; Relay Information\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e SIGA-CR\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDevice Type:\u003c\/strong\u003e Intelligent Control Relay Module\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOutput:\u003c\/strong\u003e One Form C Relay\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eContacts:\u003c\/strong\u003e N.O. \/ N.C. \/ Common\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAddresses Required:\u003c\/strong\u003e One\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Voltage:\u003c\/strong\u003e 15.2–19.95 VDC\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication:\u003c\/strong\u003e Edwards Signature\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAddressing:\u003c\/strong\u003e Electronic\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStatus Indicators:\u003c\/strong\u003e Green \/ Red LEDs\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRelay Type:\u003c\/strong\u003e Dry Contact\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum Wire Size:\u003c\/strong\u003e 12 AWG \/ 2.5 mm²\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"EDWARDS","offers":[{"title":"Default Title","offer_id":54082209775923,"sku":"SIGA-CR","price":70.99,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1000\/9785\/1699\/files\/edwards-siga-cr-plena-v2.jpg?v=1795214283"},{"product_id":"edwards-siga-ct1","title":"EDWARDS SIGA-CT1 Single Input Module","description":"\u003cp class=\"isSelectedEnd\"\u003eThe \u003cstrong\u003eEdwards SIGA-CT1\u003c\/strong\u003e is a Signature Series intelligent single input module designed to connect normally open dry-contact initiating devices to compatible Edwards addressable fire alarm systems. It provides one supervised input circuit for monitoring devices such as pull stations, waterflow switches, valve tamper switches, and other contact-type initiating equipment.\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003eThe SIGA-CT1 incorporates onboard microprocessor technology, intelligent Signature communication, automatic device mapping, and electronic addressing. Its compact module design allows conventional contact devices to become individually identified points within an intelligent commercial fire alarm system.\u003c\/p\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch3\u003eProduct Functions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProvides one supervised input circuit\u003c\/li\u003e\n\u003cli\u003eMonitors normally open dry contacts\u003c\/li\u003e\n\u003cli\u003eSupports conventional initiating devices\u003c\/li\u003e\n\u003cli\u003eProvides individual addressable point identification\u003c\/li\u003e\n\u003cli\u003eReports alarm conditions to the fire alarm control panel\u003c\/li\u003e\n\u003cli\u003eReports supervisory conditions when programmed\u003c\/li\u003e\n\u003cli\u003eMonitors field wiring integrity\u003c\/li\u003e\n\u003cli\u003eSupports automatic device mapping\u003c\/li\u003e\n\u003cli\u003eSupports electronic addressing\u003c\/li\u003e\n\u003cli\u003eProvides intelligent Signature Series communication\u003c\/li\u003e\n\u003cli\u003eSupports commercial fire alarm systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDevice Applications\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003eThe SIGA-CT1 can be used to monitor a variety of normally open dry-contact devices.\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003eTypical monitored equipment may include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eManual pull stations\u003c\/li\u003e\n\u003cli\u003eSprinkler waterflow switches\u003c\/li\u003e\n\u003cli\u003eValve tamper switches\u003c\/li\u003e\n\u003cli\u003ePressure switches\u003c\/li\u003e\n\u003cli\u003eSupervisory switches\u003c\/li\u003e\n\u003cli\u003eConventional heat detectors\u003c\/li\u003e\n\u003cli\u003eDoor position contacts\u003c\/li\u003e\n\u003cli\u003eEquipment status contacts\u003c\/li\u003e\n\u003cli\u003eOther approved dry-contact initiating devices\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Identification\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Edwards\u003cbr\u003e\u003cstrong\u003eSeries:\u003c\/strong\u003e Signature Series\u003cbr\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e SIGA-CT1\u003cbr\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Single Input Module\u003cbr\u003e\u003cstrong\u003eInput Channels:\u003c\/strong\u003e 1\u003cbr\u003e\u003cstrong\u003eInput Type:\u003c\/strong\u003e Normally Open Dry Contact\u003cbr\u003e\u003cstrong\u003eCircuit Function:\u003c\/strong\u003e Supervised Input Monitoring\u003cbr\u003e\u003cstrong\u003eAddressing:\u003c\/strong\u003e Electronic\u003cbr\u003e\u003cstrong\u003eDevice Mapping:\u003c\/strong\u003e Automatic Device Mapping\u003cbr\u003e\u003cstrong\u003eCommunication:\u003c\/strong\u003e Signature Series Intelligent Communication\u003cbr\u003e\u003cstrong\u003eInstallation:\u003c\/strong\u003e Electrical Box \/ Approved Enclosure\u003cbr\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e Commercial Addressable Fire Alarm Systems\u003c\/p\u003e","brand":"EDWARDS","offers":[{"title":"Default Title","offer_id":54082209874227,"sku":"SIGA-CT1","price":61.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1000\/9785\/1699\/files\/edwards-siga-ct1-plena-v2.jpg?v=1795214283"},{"product_id":"edwards-siga-ct2","title":"EDWARDS SIGA-CT2 Dual Input Module","description":"\u003cp\u003eThe \u003cstrong\u003eEdwards EST SIGA-CT2\u003c\/strong\u003e is an intelligent analog addressable dual input module designed to connect and supervise two Class B normally-open dry contact initiating device circuits (IDCs) on the Signature Series signaling line circuit (SLC).\u003c\/p\u003e\n\u003cp\u003eEach input circuit is independently programmable using installer-selected “personality codes” downloaded from the Signature loop controller. Supported applications include Alarm (latching), Alarm with delayed latching (waterflow), Supervisory, and Monitor functions.\u003c\/p\u003e\n\u003cp\u003eThe module mounts in a standard North American 1-gang electrical box and provides separate I\/O and data loop connections. It incorporates onboard microprocessor intelligence for signal analysis and alarm decision-making, and supports automatic device mapping and electronic addressing through the loop controller or SIGA-PRO programming tool.\u003c\/p\u003e","brand":"EDWARDS","offers":[{"title":"Default Title","offer_id":54082209972531,"sku":"SIGA-CT2","price":79.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1000\/9785\/1699\/files\/edwards-siga-ct2-plena-v2.jpg?v=1795214283"},{"product_id":"edwards-siga-im2","title":"EDWARDS SIGA-IM2 Fault Isolator Module","description":"\u003ch3\u003eThe Edwards SIGA-IM2 Isolator Module\u003c\/h3\u003e\n\u003cp data-pm-slice=\"1 1 []\"\u003eis an addressable device that protects a signaling line circuit (SLC) from a to wire-to-wire short. The SIGA-IM2 module monitors line voltages and opens the data to detect a short, isolating the short between the two modules located closest to the short. The loop controller assigns an address to the SIGA-IM module. The module uses one detector address on the SLC.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe Edwards SIGA-IM2 Isolator Module is part of GE Security’s Signature Series system. This intelligent device enables part of the Signature data loop to continue operating should a short circuit occur. The module will be wired into a Class A data loop at any point. For example, if a fault occurs, the isolator cuts power to all devices beyond the isolator on the loop as follows:\u003c\/li\u003e\n\u003cli\u003ea short on the line critically causes all isolators to open within 23 msec.\u003c\/li\u003e\n\u003cli\u003eat 10 msec intervals, beginning on one side of the Class A circuit nearest the loop, the isolators close to providing the next isolator down the line with power.\u003c\/li\u003e\n\u003cli\u003ewhen the isolator next to the short closes, it reopens within 10 msec.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eOnce activated, the line fault isolator continuously checks the faulted side of the loop to determine if the short still exists. Also, when the fault is removed, is automatically restores the entire data loop to a normal condition. The microprocessor in every module gives at least three important benefits Self-diagnostics and History Log, Mapping, and Fast, Stable Communication.\u003c\/p\u003e","brand":"EDWARDS","offers":[{"title":"Default Title","offer_id":54082210267443,"sku":"SIGA-IM2","price":65.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1000\/9785\/1699\/files\/edwards-siga-im2-plena-v2.png?v=1795214284"},{"product_id":"edwards-siga-mcc1","title":"EDWARDS SIGA-MCC1 Single Input Signal Module","description":"\u003cp\u003eThe \u003cstrong\u003eEdwards SIGA-MCC1\u003c\/strong\u003e Single Input Signal Module connects, a supervise Class B signal. Or an audio signal to their respective power inputs. The \u003cstrong\u003eSIGA-MCC1\u003c\/strong\u003e can connect telephone circuits. The power inputs may be polarized 24V DC. To operate audible and visible signal appliances to operate audio evacuation speakers. The SIGA-MCC1 can operate firefighter’s telephones. When configured for telephone circuits, the SIGA-MCC1 generates its ring-tone signal. They can Eliminate the need for a separate ring-tone circuit.\u003c\/p\u003e\n\u003cp\u003eEach module constantly runs self-diagnostics to provide important maintenance information. The module stores the results of the self-diagnostic in its permanent non-volatile memory. In a regular supervisory polling response, the module only needs. To communicate with the loop controller when it has something new to report.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eEdwards SIGA-MCC1 Module Single Input Signal\u003c\/strong\u003e is part of the UIO family of plug-in Signature Series modules. They function identically to the SIGA-MCC1. Take advantage of the modular flexibility and easy installation. That characterizes all UIO modules. Two- and six-module UIO motherboards are available. All wire connections are made to terminal blocks on the motherboard. Continuously running self-diagnostics update device statistics. And store them in a history log in non-volatile memory.\u003c\/p\u003e","brand":"EDWARDS","offers":[{"title":"Default Title","offer_id":54082210398515,"sku":"SIGA-MCC1","price":72.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1000\/9785\/1699\/files\/edwards-siga-mcc1-plena-v2.png?v=1795214285"},{"product_id":"edwards-siga-rel","title":"EDWARDS SIGA-REL Agent Releasing Module","description":"\u003cp\u003eThe \u003cstrong\u003eEdwards SIGA-REL\u003c\/strong\u003e is an intelligent addressable Releasing Module for Signature Series fire alarm systems. It controls deluge sprinkler, preaction sprinkler, and automatic fire-extinguishing systems. As a result, the SIGA-REL releases water, foam, CO2, Halon, clean agent, or other suppression agents on command.\u003c\/p\u003e\n\u003ch3\u003eEdwards SIGA-REL — what it controls\u003c\/h3\u003e\n\u003cp\u003eFirst, the SIGA-REL provides two supervised release circuits for solenoid-controlled release valves. In addition, it provides two supervised prerelease circuits — one for audible appliances, one for visual appliances. Furthermore, the module includes one supervised manual release input, one supervised abort input, and one zone relay output (Form C contact). The two release circuits operate in unison and cannot be controlled separately.\u003c\/p\u003e\n\u003ch3\u003eCompatible panels\u003c\/h3\u003e\n\u003cp\u003eEST2, EST3, and QuickStart fire alarm control panels. The SIGA-REL must be installed in an enclosure dedicated to the releasing system — no other devices may be in the enclosure. Approved enclosures: 2-WB series, 3-RCC series, 3-CAB series, MFC-A, RACCR series. In addition, maintain 1 in (25.4 mm) minimum clearance around the SIGA-REL per NFPA 70 NEC.\u003c\/p\u003e\n\u003ch3\u003ePower and electrical\u003c\/h3\u003e\n\u003cp\u003ePower riser input voltage: 18.4 to 27.4 VDC, power-limited. Supervisory current: 25 mA max. Alarm current: 190 mA min, 4 A max (depends on output loading). Furthermore, release circuits TB4-1\/2 and TB4-3\/4 are rated 2 A at 24 VDC max with 47K end-of-line resistor. Prerelease circuits TB5-1\/2 and TB5-3\/4 are rated 2 A at 24 VDC max with 47K EOL. Each release circuit supports a maximum of 4 release valves.\u003c\/p\u003e\n\u003ch3\u003eRequired accessories\u003c\/h3\u003e\n\u003cp\u003eRELA-EOL solenoid control relays are REQUIRED to buffer the SIGA-REL from valve solenoid spikes. For manual release: 276A-REL Manual Release Station or 278A-REL Double Action Manual Release Station (FM approved). For abort: RELA-ABT Manual Abort Station (FM approved). In addition, for service disconnect: RELA-SRV-1 Service Disconnect Switch (FM approved, normally closed, minimum 2.0 A).\u003c\/p\u003e\n\u003ch3\u003eCompatible power supplies\u003c\/h3\u003e\n\u003cp\u003e2-PPS \/ 2-PPS\/220, 2-PPS\/6A \/ 2-PPS\/6A-220, 3-BPS\/M \/ 3-BPS\/M-230, 3-PPS\/M \/ 3-PPS\/M-230. Also BPS6A \/ BPS6A\/230 and BPS10A \/ BPS10A\/230 — however, these BPS supplies are NOT compatible with FM sprinkler applications that require 90 hours of standby. The SIGA-REL is NOT compatible with the QuickStart PS6 Power Supply Card.\u003c\/p\u003e\n\u003ch3\u003eNFPA standards by suppression agent\u003c\/h3\u003e\n\u003cp\u003eNFPA 11 (low-expansion foam), NFPA 11A (medium- and high-expansion foam), NFPA 12 (CO2), NFPA 12A (Halon 1301), NFPA 13 (sprinklers), NFPA 15 (water spray), NFPA 16 (foam-water), NFPA 17 (dry chemicals), NFPA 2001 (clean agent). For NFPA 12A and NFPA 2001 agents, a separate mechanical manual release is required in addition to the SIGA-REL release station. Furthermore, the SIGA-REL is NOT designed to generate an NFPA 72 evacuation signal and does NOT meet UL 864 evacuation NAC requirements.\u003c\/p\u003e","brand":"EDWARDS","offers":[{"title":"Default Title","offer_id":54082210595123,"sku":"SIGA-REL","price":374.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1000\/9785\/1699\/files\/edwards-siga-rel-plena-v2.png?v=1795214285"},{"product_id":"edwards-siga-rm1","title":"EDWARDS SIGA-RM1 Riser Monitor Module","description":"\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMonitors telephone, audio, or power risers\u003c\/li\u003e\n\u003cli\u003eConfigurable personality codes for multiple applications\u003c\/li\u003e\n\u003cli\u003eAdjustable time delay settings\u003c\/li\u003e\n\u003cli\u003eAutomatic device mapping and electronic addressing\u003c\/li\u003e\n\u003cli\u003eSingle-gang standard mount design\u003c\/li\u003e\n\u003cli\u003eAlert status notification to control panel\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMonitoring Options:\u003c\/strong\u003e Telephone risers, 70VAC audio, 25VAC audio, or 12-24VDC risers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e Personality code selected during system setup\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperation:\u003c\/strong\u003e Loss-of-signal triggers alert status\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTime Delay:\u003c\/strong\u003e Adjustable by installer\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower:\u003c\/strong\u003e 15.2-19.95VDC from SLC loop\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMount Type:\u003c\/strong\u003e Standard 2-gang\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.4 lb\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUPC:\u003c\/strong\u003e 793016032133\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCertifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUL Listed\u003c\/li\u003e\n\u003cli\u003eSignature Series compatible\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"EDWARDS","offers":[{"title":"Default Title","offer_id":54082210693427,"sku":"SIGA-RM1","price":104.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1000\/9785\/1699\/files\/edwards-siga-rm1-plena-v2.png?v=1795214285"},{"product_id":"edwards-siga-uio2r","title":"EDWARDS SIGA-UIO2R Input Output Module","description":"\u003cp\u003eThe \u003cstrong\u003eEdwards SIGA-UIO2R\u003c\/strong\u003e is a two-position Universal Input\/Output (UIO) motherboard. It holds up to two Signature input or output modules. In addition, it provides the wiring base and riser-selection points for those modules inside the panel.\u003c\/p\u003e\n\u003ch3\u003eWhat the Edwards SIGA-UIO2R provides\u003c\/h3\u003e\n\u003cp\u003eThis motherboard organizes module mounting in a Signature system. First, two compatible Signature modules plug into its positions. Then field and riser wiring lands on its terminals. As a result, input and output modules stay neatly mounted and clearly wired.\u003c\/p\u003e\n\u003ch3\u003eKey details\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTwo-position UIO motherboard\u003c\/li\u003e\n\u003cli\u003eHosts Edwards Signature input\/output modules\u003c\/li\u003e\n\u003cli\u003eRiser-selection wiring base\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"EDWARDS","offers":[{"title":"Default Title","offer_id":54082210890035,"sku":"SIGA-UIO2R","price":78.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1000\/9785\/1699\/files\/edwards-siga-uio2r-plena-v2.png?v=1795214285"},{"product_id":"edwards-siga-wtm","title":"EDWARDS SIGA-WTM Waterflow Tamper Module","description":"\u003cp\u003eThe \u003cstrong\u003eEdwards SIGA-WTM\u003c\/strong\u003e is an intelligent addressable waterflow and tamper interface module for Edwards Signature Series loops. Specifically, it monitors one waterflow switch and one supervisory or tamper switch on a sprinkler system. As a result, both signals arrive at the panel as individually identified points.\u003c\/p\u003e\n\u003cp\u003eIn addition, the SIGA-WTM uses two device addresses on the Signature loop. Therefore, the panel can distinguish a waterflow alarm from a tamper or supervisory condition without ambiguity.\u003c\/p\u003e\n\u003ch3\u003eHow the Edwards SIGA-WTM Works\u003c\/h3\u003e\n\u003cp\u003eFirst, the waterflow input includes a built-in retard timer of approximately 16 seconds. As a result, momentary water pressure surges do not generate false alarms. Then, after the retard expires, the module reports a latching waterflow alarm.\u003c\/p\u003e\n\u003cp\u003eFurthermore, the second input handles tamper or supervisory switches. Specifically, it latches on any active condition and clears only after the panel issues a reset.\u003c\/p\u003e\n\u003cp\u003eIn addition, the module uses electronic addressing. Therefore, no dip switches or rotary dials are required during installation.\u003c\/p\u003e\n\u003ch3\u003eCritical Compatibility Note\u003c\/h3\u003e\n\u003cp\u003eThe SIGA-WTM does NOT support 2-wire smoke detectors. Therefore, do not connect conventional 2-wire smoke detectors to either input. Instead, use a SIGA-CC1 or SIGA-MM1 configured for the appropriate input type.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFunction: Intelligent waterflow + tamper\/supervisory monitor module\u003c\/li\u003e\n\u003cli\u003eInputs: 2 × Class B (waterflow ~16 s retard; tamper\/supervisory latching)\u003c\/li\u003e\n\u003cli\u003eAddresses used: 2 (one per input)\u003c\/li\u003e\n\u003cli\u003ePower: 15.2 to 19.95 VDC from the Signature SLC\u003c\/li\u003e\n\u003cli\u003eCurrent: 396 µA standby; 680 µA active\u003c\/li\u003e\n\u003cli\u003eStatus LEDs: Green (polled) and red (active\/alarm)\u003c\/li\u003e\n\u003cli\u003eIDC loop limits: 50 Ω total, 0.1 µF maximum per circuit\u003c\/li\u003e\n\u003cli\u003eMounting: Standard 1-gang electrical box\u003c\/li\u003e\n\u003cli\u003eDoes not support: 2-wire smoke detectors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatible Edwards Panels\u003c\/h3\u003e\n\u003cp\u003eThe SIGA-WTM works with Edwards Signature-loop control panels. Specifically, it is compatible with:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEdwards EST3\u003c\/li\u003e\n\u003cli\u003eEdwards EST3X\u003c\/li\u003e\n\u003cli\u003eEdwards iO Series controllers via the Signature Loop Controller\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eHowever, before ordering, verify your panel’s firmware revision against the current Edwards Signature compatibility list.\u003c\/p\u003e","brand":"EDWARDS","offers":[{"title":"Default Title","offer_id":54082210988339,"sku":"SIGA-WTM","price":85.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1000\/9785\/1699\/files\/edwards-siga-wtm-plena-v2.png?v=1795214285"},{"product_id":"farenhyt-ecs-nvcm","title":"FARENHYT ECS-NVCM Network Voice Control Module","description":"\u003cp\u003eThe \u003cstrong\u003eFarenhyt ECS-NVCM\u003c\/strong\u003e is a Network Voice Control Module for the Farenhyt IFP-2100ECS and IFP-300ECS Emergency Communication System panels.\u003c\/p\u003e\n\u003ch3\u003eSystem Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMounted inside the ECS panel enclosure, it provides a supervised microphone for live communication and serves as the networked audio interface for the Emergency Communication System, with support for optional SK-FML\/SK-FSL fiber-optic modules.\u003c\/li\u003e\n\u003cli\u003eOperates on 24VDC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Details\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eManufacturer: Farenhyt\u003c\/li\u003e\n\u003cli\u003eSKU: ECS-NVCM\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eBefore Ordering\u003c\/h3\u003e\n\u003cp\u003eMatch ECS-NVCM to the part number specified for your system. Check system compatibility and required accessories in the manufacturer's documentation.\u003c\/p\u003e","brand":"FARENHYT","offers":[{"title":"Default Title","offer_id":54082211414323,"sku":"ECS-NVCM","price":374.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1000\/9785\/1699\/files\/farenhyt-ecs-nvcm-plena-v2.png?v=1795214413"},{"product_id":"farenhyt-idp-control","title":"FARENHYT IDP-CONTROL Addressable Supervised Control Module","description":"\u003cp\u003eThe \u003cstrong\u003eFarenhyt IDP-CONTROL\u003c\/strong\u003e is an addressable notification module from Silent Knight. Specifically, it provides supervised drive to load devices powered by an external supply.\u003c\/p\u003e\n\u003cp\u003eFirst, the IDP-CONTROL connects to the host panel’s SLC loop and is given an address. Then it drives notification appliances such as bells, horns, and strobes. As a result, the panel can activate audible and visual notification on a supervised circuit.\u003c\/p\u003e\n\u003ch3\u003eFarenhyt IDP-CONTROL Key Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAddressable notification (control) module for Silent Knight \/ Honeywell Farenhyt panels\u003c\/li\u003e\n\u003cli\u003eSupervises wiring to external-powered load devices (bells, horns, strobes)\u003c\/li\u003e\n\u003cli\u003eClass A and Class B supervision options\u003c\/li\u003e\n\u003cli\u003eTwo pairs of output termination points for fault-tolerant wiring\u003c\/li\u003e\n\u003cli\u003eMounts directly into a 4\" square electrical box (minimum 2-1\/8\" depth)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhere the IDP-CONTROL Is Used\u003c\/h3\u003e\n\u003cp\u003eSpecifically, the IDP-CONTROL is compatible with the IFP-2000, IFP-1000, IFP-100, and IFP-50 intelligent fire alarm panels. Therefore, it is the standard NAC driver across the Farenhyt IFP family.\u003c\/p\u003e\n\u003cp\u003eFurthermore, the external power and the SLC loop are kept separate. As a result, large notification loads do not draw down the SLC.\u003c\/p\u003e","brand":"FARENHYT","offers":[{"title":"Default Title","offer_id":54082211512627,"sku":"IDP-CONTROL","price":52.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1000\/9785\/1699\/files\/farenhyt-idp-control-plena-v2.png?v=1795214413"},{"product_id":"fire-lite-411rk","title":"FIRE-LITE 411RK Relay Kit, Two Programmable Form-C Relays for 411UDAC","description":"\u003cp\u003eThe \u003cstrong\u003eFIRE-LITE 411RK\u003c\/strong\u003e is the optional relay kit for the Fire-Lite Fire-Watch 411UDAC fire alarm communicator. It adds two dry auxiliary Form-C relays that install on the 411UDAC main circuit board and are programmable for activation on fire alarm, host panel trouble, fire supervisory, process monitoring, total communications failure and DACT trouble.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTwo dry auxiliary Form-C relays\u003c\/li\u003e\n\u003cli\u003eInstalls on the 411UDAC main circuit board\u003c\/li\u003e\n\u003cli\u003eProgrammable: fire alarm, host panel trouble, fire supervisory, process monitoring, total communication failure, DACT trouble\u003c\/li\u003e\n\u003cli\u003eFor the 411UDAC only\u003c\/li\u003e\n\u003cli\u003eManufacturer: Fire-Lite | Part Number: 411RK | Condition: New\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eLater 411UDAC Rev 2 boards include two Form-C relays on board - confirm your 411UDAC revision. Always verify compatibility with your system and local code requirements before ordering.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Fire-Lite Alarms (Honeywell)\u003cbr\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e 411RK\u003cbr\u003e\n\u003cstrong\u003eContacts:\u003c\/strong\u003e 2 Form-C, dry\u003cbr\u003e\n\u003cstrong\u003eContact Rating:\u003c\/strong\u003e 2.0 A @ 30 VDC (resistive) or 0.5 A @ 30 VAC (resistive)\u003cbr\u003e\n\u003cstrong\u003eUsed With:\u003c\/strong\u003e Fire-Lite 411UDAC\u003c\/p\u003e","brand":"FIRE-LITE","offers":[{"title":"Default Title","offer_id":54082212167987,"sku":"411RK","price":23.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1000\/9785\/1699\/files\/PlenaSupplyComingSoon_53438168-f04e-47c8-a980-6f0ee3d24365.png?v=1795208974"},{"product_id":"fire-lite-ann-sec","title":"FIRE-LITE ANN-SEC Optional Secondary ANN-BUS Interface Module","description":"\u003cp\u003eThe \u003cstrong\u003eFIRE-LITE ANN-SEC\u003c\/strong\u003e is an optional secondary ANN-BUS interface module that provides another ANN-BUS port on compatible Fire-Lite control panels, for more wiring flexibility of ANN-BUS annunciators and modules.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAdds a secondary ANN-BUS port to the FACP\u003c\/li\u003e\n\u003cli\u003eMore wiring flexibility for ANN-BUS annunciators and modules\u003c\/li\u003e\n\u003cli\u003eOn the MS-9050UD(E), used only with firmware 3.0 or higher\u003c\/li\u003e\n\u003cli\u003eManufacturer: Fire-Lite | Part Number: ANN-SEC | Condition: New\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAlways verify compatibility with your system and local code requirements before ordering.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Fire-Lite Alarms (Honeywell)\u003cbr\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e ANN-SEC\u003cbr\u003e\n\u003cstrong\u003eFunction:\u003c\/strong\u003e Secondary ANN-BUS interface\u003cbr\u003e\n\u003cstrong\u003eCompatibility Note:\u003c\/strong\u003e MS-9050UD(E): firmware 3.0 or higher\u003c\/p\u003e","brand":"FIRE-LITE","offers":[{"title":"Default Title","offer_id":54082212430131,"sku":"ANN-SEC","price":194.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1000\/9785\/1699\/files\/fire-lite-ann-sec-plena-v2.png?v=1795214413"},{"product_id":"fire-lite-mdf-300","title":"FIRE-LITE MDF-300 Dual Monitor Module","description":"\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong\u003eFire-Lite MDF-300 Dual Monitor Module\u003c\/strong\u003e is an intelligent addressable interface module designed for compatible Fire-Lite fire alarm control panels. It provides \u003cstrong\u003etwo independently monitored initiating device circuits (IDCs)\u003c\/strong\u003e for connecting conventional normally open contact devices to an addressable signaling line circuit.\u003c\/p\u003e\n\u003cp\u003eThe MDF-300 is useful where two conventional initiating or supervisory circuits are located near each other, reducing the number of individual monitor modules required.\u003c\/p\u003e\n\u003ch3\u003eProduct Functions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProvides two independently monitored inputs\u003c\/li\u003e\n\u003cli\u003eIntelligent addressable monitor module\u003c\/li\u003e\n\u003cli\u003eSupports Class B initiating device circuits\u003c\/li\u003e\n\u003cli\u003eMonitors normally open contact devices\u003c\/li\u003e\n\u003cli\u003eProvides individual status reporting for both inputs\u003c\/li\u003e\n\u003cli\u003eUses rotary decimal address switches\u003c\/li\u003e\n\u003cli\u003eSupports LiteSpeed communication\u003c\/li\u003e\n\u003cli\u003eProvides LED status indication\u003c\/li\u003e\n\u003cli\u003eSupervises field wiring for open-circuit conditions\u003c\/li\u003e\n\u003cli\u003eSupports compatible end-of-line resistors\u003c\/li\u003e\n\u003cli\u003ePowered directly from the SLC\u003c\/li\u003e\n\u003cli\u003eRequires no separate external power\u003c\/li\u003e\n\u003cli\u003eDesigned for compatible Fire-Lite addressable systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical \u0026amp; Interface Information\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e MDF-300\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDevice Type:\u003c\/strong\u003e Intelligent Dual Monitor Module\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInputs:\u003c\/strong\u003e Two\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCircuit Type:\u003c\/strong\u003e Class B\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMonitored Devices:\u003c\/strong\u003e Normally Open Contacts\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication:\u003c\/strong\u003e LiteSpeed\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAddressing:\u003c\/strong\u003e Rotary Decimal Switches\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Voltage:\u003c\/strong\u003e 15–32 VDC\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum SLC Current:\u003c\/strong\u003e Approximately 750 µA\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExternal Power:\u003c\/strong\u003e Not Required\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eField Wiring:\u003c\/strong\u003e Supervised\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e 4-inch square electrical box\u003c\/p\u003e","brand":"FIRE-LITE","offers":[{"title":"Default Title","offer_id":54082214166835,"sku":"MDF-300","price":120.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1000\/9785\/1699\/files\/fire-lite-mdf-300-plena-v2.webp?v=1795214414"},{"product_id":"fire-lite-mmf-302","title":"FIRE-LITE MMF-302 Interface Module","description":"\u003cp\u003eThe \u003cstrong\u003eFirelite MMF-302\u003c\/strong\u003e Interface Module is intended for use in addressable two-wire systems, where the individual address of each module is selected using the built-in rotary switches. Also, this module allows addressable panels to interface and monitors two-wire conventional smoke detectors. Besides, it transmits the status (normal, open, or alarm) of one full zone of conventional detectors back to the control panel. All two-wire detectors being monitored must be UL compatible with this module. Furthermore, the Firelite MMF-302 has a panel-controlled LED indicator and can be used to replace an M302 module in existing systems.\u003c\/p\u003e\n\u003cp\u003eThis information is include as a quick reference installation guide. Refer to the control panel installation manual for detailed system information. If the modules will be install in an existing operational system, inform the operator as well as local authority that the system will be temporarily out of service. Disconnect power to the control panel before installing the modules. In addition, the Firelite MMF-302 mounts directly to 4-inch square electrical boxes (see Figure 2). The box must have a minimum depth of 21⁄8 inches. Surface mounted electrical boxes (SMB500) are available.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures \/ Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNormal Operating Voltage: \u003cstrong\u003e15 to 32 VDC\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eEOL Resistance: \u003cstrong\u003e3.9K ohms\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eTemperature Range: \u003cstrong\u003e32˚F to 120˚F (0˚C to 49˚C)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eHumidity:\u003cstrong\u003e 10% to 93% Non-condensing\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eDimensions: \u003cstrong\u003e41⁄2˝ H × 4˝ W × 11⁄4˝ D (Mounts to a 4˝ square by 21⁄8˝ deep box.)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eMaximum IDC Resistance: \u003cstrong\u003e25 Ohms\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"FIRE-LITE","offers":[{"title":"Default Title","offer_id":54082214265139,"sku":"MMF-302","price":87.99,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1000\/9785\/1699\/files\/fire-lite-mmf-302-plena-v2.webp?v=1795214414"},{"product_id":"fire-lite-pam-1","title":"FIRE-LITE PAM-1 Multi-Voltage Relay Module, 24 VDC\/24 VAC\/120 VAC, SPDT with LED","description":"\u003cp\u003eThe \u003cstrong\u003eFIRE-LITE PAM-1\u003c\/strong\u003e is an encapsulated multi-voltage relay module with flying leads (manufactured by Space Age Electronics, SSU-PAM-1). It provides 10.0 A Form C contacts and may be energized by one of three input voltages: 24 VDC, 24 VAC or 120 VAC. A red LED indicates the relay coil is energized.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCoil energized by 24 VDC, 24 VAC or 120 VAC\u003c\/li\u003e\n\u003cli\u003eOne SPDT dry Form C contact\u003c\/li\u003e\n\u003cli\u003eRed LED indicates coil energized\u003c\/li\u003e\n\u003cli\u003eDC inputs polarity sensitive and diode protected\u003c\/li\u003e\n\u003cli\u003e100% potted (sealed) with 12 in. \/ 18 AWG flying leads; wire-nuts, self-tapping screw and double-sided tape provided\u003c\/li\u003e\n\u003cli\u003eManufacturer: Fire-Lite | Part Number: PAM-1 | Condition: New\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAlways verify compatibility with your system and local code requirements before ordering.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Fire-Lite Alarms (Honeywell)\u003cbr\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e PAM-1\u003cbr\u003e\n\u003cstrong\u003eCoil Voltage:\u003c\/strong\u003e 24 VDC \/ 24 VAC \/ 120 VAC\u003cbr\u003e\n\u003cstrong\u003eCurrent:\u003c\/strong\u003e 15 mA @ 24 VDC; 50 mA @ 24 VAC; 30 mA @ 120 VAC\u003cbr\u003e\n\u003cstrong\u003eContacts:\u003c\/strong\u003e (1) SPDT dry Form C\u003cbr\u003e\n\u003cstrong\u003eContact Ratings:\u003c\/strong\u003e 7 A @ 24 VDC; 10 A @ 120 VAC\u003cbr\u003e\n\u003cstrong\u003eAmbient Temperature:\u003c\/strong\u003e 32°F to 120°F (0°C to 49°C)\u003cbr\u003e\n\u003cstrong\u003eListings:\u003c\/strong\u003e UL; CSFM 7300-1004:101; MEA 73-92-E Vol. 21\u003c\/p\u003e","brand":"FIRE-LITE","offers":[{"title":"Default Title","offer_id":54082214363443,"sku":"PAM-1","price":18.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1000\/9785\/1699\/files\/fire-lite-pam-1-plena-v2.png?v=1795214414"},{"product_id":"gamewell-1100-0451","title":"GAMEWELL 1100-0451 INCC-TEL Fire Fighter Phone Module for E3 Series LOC-TEL","description":"\u003cp\u003eThe \u003cstrong\u003eGAMEWELL 1100-0451 (INCC-TEL)\u003c\/strong\u003e is the Fire Fighter Phone Module for the Gamewell-FCI E3 Series LOC-TEL local operating console, used in emergency voice\/mass notification command centers. It mounts in the two-slot E3ID2-TA inner door alongside an ASM-16 addressable switch module.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFire fighter telephone module for the E3 Series LOC-TEL\u003c\/li\u003e\n\u003cli\u003eMounts in the E3ID2-TA two-slot inner door (with one ASM-16 Addressable Switch Module)\u003c\/li\u003e\n\u003cli\u003eWorks with the AOM-TELF telephone control module and AOM-TEL-FL telephone filters\u003c\/li\u003e\n\u003cli\u003eLOC-TEL is listed under UL 2572 for Mass Notification\u003c\/li\u003e\n\u003cli\u003eManufacturer: Gamewell-FCI | Part Number: 1100-0451 | Condition: New\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eLOC-TEL enclosure, inner door, AOM-TELF and handsets sold separately. Always verify compatibility with your system and local code requirements before ordering.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Gamewell-FCI (Honeywell)\u003cbr\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e 1100-0451\u003cbr\u003e\n\u003cstrong\u003eModel Name:\u003c\/strong\u003e INCC-TEL\u003cbr\u003e\n\u003cstrong\u003eSystem:\u003c\/strong\u003e Gamewell-FCI E3 Series LOC-TEL\u003cbr\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e E3ID2-TA inner door, 2 slots\u003c\/p\u003e","brand":"GAMEWELL","offers":[{"title":"Default Title","offer_id":54082214920499,"sku":"1100-0451","price":392.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1000\/9785\/1699\/files\/gamewell-1100-0451-plena-v2.png?v=1795214416"},{"product_id":"gamewell-amm-2f","title":"GAMEWELL-FCI AMM-2F Mini Monitor Module","description":"\u003cp class=\"isSelectedEnd\"\u003eThe \u003cstrong\u003eGamewell-FCI AMM-2F\u003c\/strong\u003e is an addressable mini monitor module designed for compatible Gamewell-FCI fire alarm systems. Specifically, it provides one supervised \u003cstrong\u003eStyle B (Class B) initiating device circuit (IDC)\u003c\/strong\u003e for monitoring normally open dry-contact initiating devices and reporting their status to the fire alarm control panel.\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003eBuilt for dependable commercial operation, the AMM-2F features a compact design, rotary decimal address switches, a bi-color LED status indicator, and flexible programming options. In addition, its miniature size allows installation inside manual pull stations, electrical boxes, duct detector housings, and other initiating device enclosures.\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003eThis product is intended exclusively for commercial fire alarm installations and is not surveillance equipment, communications equipment, consumer electronics, tracking equipment, or recording devices.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003ch3\u003eCompact Mini Module\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003eThe AMM-2F features a compact lightweight design that allows installation inside manual pull stations, electrical boxes, duct detector housings, and other initiating device enclosures. As a result, installers can add addressable monitoring without requiring large mounting cabinets.\u003c\/p\u003e\n\u003ch3\u003eAddressable Monitoring\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003eThe module converts compatible normally open dry-contact devices into individually identifiable addressable points. Consequently, the fire alarm control panel can display the exact location of the monitored device during an alarm or supervisory condition.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Gamewell-FCI\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e AMM-2F\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Addressable Mini Monitor Module\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003eInitiating Device Circuit:\u003c\/strong\u003e One Style B (Class B)\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003eSupported Devices:\u003c\/strong\u003e Normally Open Dry Contacts\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003eCommunication Protocol:\u003c\/strong\u003e Velociti®\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003eOperating Voltage:\u003c\/strong\u003e 15–32 VDC\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003eAverage Standby Current:\u003c\/strong\u003e 375 µA (Velociti Mode)\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003eAverage Standby Current:\u003c\/strong\u003e 350 µA (CLIP Mode)\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003eMaximum Alarm Current:\u003c\/strong\u003e 600 µA\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003eEnd-of-Line Resistor:\u003c\/strong\u003e 47 kΩ\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003eStatus Indicator:\u003c\/strong\u003e Bi-Color LED\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003eAddressing Method:\u003c\/strong\u003e Rotary Decimal Switches\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 32°F to 120°F (0°C to 49°C)\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003eRelative Humidity:\u003c\/strong\u003e 10%–93% Non-Condensing\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e 2.75 × 1.30 × 0.50 in (70 × 33 × 13 mm)\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003eWire Leads:\u003c\/strong\u003e 6 in (150 mm) Minimum\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e Standard Single-Gang Electrical Box\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003eListings:\u003c\/strong\u003e UL Listed, FM Approved, CSFM Approved (verify approvals for your specific application).\u003c\/p\u003e","brand":"GAMEWELL","offers":[{"title":"Default Title","offer_id":54082215117107,"sku":"AMM-2F","price":62.99,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1000\/9785\/1699\/files\/gamewell-amm-2f-plena-v2.jpg?v=1795214415"},{"product_id":"gamewell-amm-2if","title":"GAMEWELL-FCI AMM-2IF Addressable Dual Monitor Module","description":"\u003cp\u003eThe \u003cstrong\u003eGamewell FCI AMM-2IF Addressable Dual Monitor Module\u003c\/strong\u003e is an advanced device in fire alarm systems. It monitors and reports the status of two dry-contact devices simultaneously. As part of the Gamewell FCI addressable system, the AMM-2IF enhances the monitoring of critical devices like water flow switches, pressure switches, and supervisory equipment. This module increases system flexibility, reliability, and scalability, making it ideal for commercial, industrial, and institutional applications.\u003c\/p\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Monitoring Capability\u003c\/strong\u003e: The AMM-2IF monitors two separate devices at once. This feature boosts system efficiency by allowing the tracking of multiple devices within one module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAddressable Technology\u003c\/strong\u003e: Like all Gamewell FCI modules, the AMM-2IF is addressable. Each module has a unique ID, enabling the control panel to pinpoint its exact location and the devices it monitors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReal-Time Status Reporting\u003c\/strong\u003e: The module provides real-time updates on device conditions. This allows fire safety teams to respond quickly to any changes, improving system efficiency and reducing response times.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeamless Integration\u003c\/strong\u003e: The AMM-2IF works seamlessly with Gamewell FCI’s addressable fire alarm control panels. This compatibility simplifies system management and allows for easier expansion or modification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide Device Compatibility\u003c\/strong\u003e: The AMM-2IF supports a broad range of dry-contact devices, including water flow switches, pressure switches, and supervisory equipment. This versatility makes it adaptable to many different fire alarm systems.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GAMEWELL","offers":[{"title":"Default Title","offer_id":54082215248179,"sku":"AMM-2IF","price":96.95,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1000\/9785\/1699\/files\/gamewell-amm-2if-plena-v2.jpg?v=1795214415"},{"product_id":"gamewell-amm-4f","title":"GAMEWELL-FCI AMM-4F Addressable Monitor Module","description":"\u003cp\u003eThe \u003cstrong\u003eGamewell AMM-4F Addressable Monitor Module\u003c\/strong\u003e plays a critical role in modern fire alarm systems. It actively monitors and reports the status of dry-contact devices, such as water flow switches, pressure switches, and supervisory devices. This allows the system to ensure comprehensive fire protection. As an addressable module, the AMM-4F has a unique identifier within the system, which allows the control panel to track it precisely. This capability is especially valuable in large, complex facilities, such as commercial buildings, industrial plants, and institutions.\u003c\/p\u003e\n\u003ch4\u003eKey Features of the Gamewell AMM-4F:\u003c\/h4\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eAddressable Technology\u003c\/strong\u003e: The system assigns the AMM-4F a unique address, allowing the control panel to identify the module and the devices it monitors. This increases the efficiency and accuracy of system management.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDevice Monitoring\u003c\/strong\u003e: The module monitors a wide range of dry-contact devices, including water flow switches, pressure switches, and supervisory systems. This feature ensures a comprehensive safety solution by covering not only active fire protection measures but also supporting systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReal-Time Reporting\u003c\/strong\u003e: The AMM-4F provides immediate updates on the status of monitored devices. By offering real-time reporting, the module helps fire safety teams act quickly and reduce response times during emergencies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeamless Integration\u003c\/strong\u003e: The module integrates smoothly with Gamewell’s addressable fire alarm control panels, allowing the system to communicate across multiple devices. This integration simplifies system expansion and enhances scalability, making the solution adaptable to various building sizes and requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupervisory Monitoring\u003c\/strong\u003e: The AMM-4F also supports supervisory monitoring, which tracks critical equipment like valves and pumps. Early detection of issues within these systems can prevent failures and improve system reliability.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GAMEWELL","offers":[{"title":"Default Title","offer_id":54082215477555,"sku":"AMM-4F","price":76.95,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1000\/9785\/1699\/files\/gamewell-amm-4f-plena-v2.webp?v=1795214415"},{"product_id":"gamewell-aom-2rf","title":"GAMEWELL-FCI AOM-2RF Control Relay","description":"\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003eGamewell FCI AOM-2RF Control Relay\u003c\/strong\u003e\u003cspan\u003e is an essential module in fire alarm systems, providing control and relay functions for various devices. This module allows fire alarm systems to control external devices like doors, HVAC systems, and other critical equipment for fire safety. The AOM-2RF is ideal for facilities that integrate fire alarm systems with other safety or control systems. It ensures reliable control and feedback, enhancing the overall fire protection system.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eKey Features of the Gamewell FCI AOM-2RF:\u003c\/h4\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Relay Functionality\u003c\/strong\u003e: The AOM-2RF activates or deactivates connected devices during an alarm. This is crucial for controlling fire doors, fans, dampers, and other systems that must respond to an emergency.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAddressable Technology\u003c\/strong\u003e: The AOM-2RF is part of the addressable fire alarm system. It has a unique address, allowing the control panel to identify and manage it precisely. This improves system organization and control, especially in large or complex installations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReal-Time Monitoring and Reporting\u003c\/strong\u003e: The module provides real-time status updates to the control panel. This helps fire safety personnel respond quickly if issues arise, ensuring system reliability during an emergency.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVersatile Applications\u003c\/strong\u003e: The AOM-2RF controls a wide range of devices, such as alarm signaling devices, door holders, and ventilation systems. Its flexibility makes it suitable for various building types, from commercial complexes to industrial sites.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeamless Integration\u003c\/strong\u003e: The AOM-2RF integrates easily with Gamewell FCI’s addressable fire alarm control panels. This integration streamlines system management and allows for easy system expansion or modifications.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GAMEWELL","offers":[{"title":"Default Title","offer_id":54082215608627,"sku":"AOM-2RF","price":66.99,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1000\/9785\/1699\/files\/gamewell-aom-2rf-plena-v2.jpg?v=1795214415"},{"product_id":"gamewell-aom-2sf","title":"GAMEWELL-FCI AOM-2SF Supervised Control Module","description":"\u003cp\u003eThe \u003cstrong\u003eGamewell FCI AOM-2SF Supervised Control Module\u003c\/strong\u003e is an essential component in modern fire alarm systems. Designed for controlling and supervising electrical devices, this module ensures reliable operation and real-time status reporting within fire alarm systems. It allows for the supervision of connected devices while offering control over critical equipment such as alarm signaling, doors, and other safety systems. The AOM-2SF enhances system performance and safety, making it suitable for various applications, including commercial, industrial, and institutional settings.\u003c\/p\u003e\n\u003ch4\u003eKey Features:\u003c\/h4\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupervised Control\u003c\/strong\u003e: The AOM-2SF supervises the status of connected devices and provides immediate alerts in case of any fault, ensuring that the system always operates correctly. This feature is crucial for maintaining system integrity and ensuring quick responses to potential issues.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAddressable Technology\u003c\/strong\u003e: The AOM-2SF is part of the addressable fire alarm system. This means it has a unique address within the system, allowing for precise identification and control. The system can quickly pinpoint the location of the module and any connected devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVersatile Control Capabilities\u003c\/strong\u003e: The module is designed to control various devices, such as door holders, alarm signaling devices, and other critical equipment. This versatility makes it adaptable to a wide range of fire alarm system configurations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReal-Time Monitoring and Reporting\u003c\/strong\u003e: The AOM-2SF provides real-time updates on the operational status of the devices it supervises. This feature ensures that fire safety personnel can quickly address any issues, minimizing response time during emergencies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeamless Integration\u003c\/strong\u003e: The module integrates effortlessly with Gamewell FCI’s addressable fire alarm control panels, ensuring smooth communication across the entire system. Its compatibility makes it easy to expand or modify existing fire alarm systems without disruption.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GAMEWELL","offers":[{"title":"Default Title","offer_id":54082215706931,"sku":"AOM-2SF","price":80.95,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1000\/9785\/1699\/files\/gamewell-aom-2sf-plena-v2.jpg?v=1795214415"},{"product_id":"notifier-4xzm","title":"NOTIFIER 4XZM Zone Relay Module, Form-C Relays (SFP-2404)","description":"\u003cp\u003eThe \u003cstrong\u003eNOTIFIER 4XZM\u003c\/strong\u003e zone relay module is an optional plug-in board that provides Form-C relay contacts to the fire alarm control panel: four zone alarm relays plus one system alarm and one system trouble relay. In the SFP-2402\/2404 series it is used with the SFP-2404 only.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFour zone alarm Form-C relays\u003c\/li\u003e\n\u003cli\u003eOne system alarm and one system trouble Form-C relay\u003c\/li\u003e\n\u003cli\u003ePlug-in option module for the panel main board (SFP-2404)\u003c\/li\u003e\n\u003cli\u003eManufacturer: Notifier | Part Number: 4XZM | Condition: New\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eObserve separation between power-limited and nonpower-limited wiring per the panel manual. Always verify compatibility with your system and local code requirements before ordering.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Notifier (Honeywell)\u003cbr\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e 4XZM\u003cbr\u003e\n\u003cstrong\u003eRelays:\u003c\/strong\u003e 4 zone alarm + 1 system alarm + 1 system trouble, Form-C\u003cbr\u003e\n\u003cstrong\u003eCompatibility:\u003c\/strong\u003e SFP-2404 (per SFP-2402\/2404 manual)\u003c\/p\u003e","brand":"NOTIFIER","offers":[{"title":"Default Title","offer_id":54082219868467,"sku":"4XZM","price":115.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1000\/9785\/1699\/files\/notifier-4xzm-plena-v2.png?v=1795214416"},{"product_id":"notifier-fcm-1","title":"NOTIFIER FCM-1 Control Module","description":"\u003cp\u003eThe \u003cstrong\u003eNotifier FCM-1 Control Module\u003c\/strong\u003e is a versatile and reliable device designed to expand the functionality of fire alarm systems. This control module enables easy integration of external control devices, providing enhanced flexibility and efficiency for your fire safety needs.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegration with Fire Alarm Systems\u003c\/strong\u003e: The \u003cstrong\u003eFCM-1 Control Module\u003c\/strong\u003e seamlessly integrates with Notifier’s fire alarm systems, allowing for extended capabilities and greater flexibility in system control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVersatile Input\/Output Capabilities\u003c\/strong\u003e: It supports a variety of input and output devices, including \u003cstrong\u003einitiating devices\u003c\/strong\u003e, \u003cstrong\u003enotification appliances\u003c\/strong\u003e, and \u003cstrong\u003erelays\u003c\/strong\u003e, making it suitable for diverse fire safety applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact Design\u003c\/strong\u003e: The module is compact and easy to install, ensuring a clean and organized setup in your fire alarm system without taking up unnecessary space.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReliable Performance\u003c\/strong\u003e: Built to provide consistent and dependable performance, the FCM-1 ensures that all connected devices respond effectively during emergencies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConvenient Monitoring\u003c\/strong\u003e: The module features \u003cstrong\u003estatus indicators\u003c\/strong\u003e, offering real-time monitoring of connected devices for easy troubleshooting and system management.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel\u003c\/strong\u003e: FCM-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType\u003c\/strong\u003e: Control Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatibility\u003c\/strong\u003e: Works with Notifier fire alarm systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput\/Output\u003c\/strong\u003e: Supports a variety of initiating and notification devices\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStatus Indicators\u003c\/strong\u003e: Provides real-time monitoring for connected devices\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"NOTIFIER","offers":[{"title":"Default Title","offer_id":54082224488755,"sku":"FCM-1","price":81.95,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1000\/9785\/1699\/files\/notifier-fcm-1-plena-v2.png?v=1795214417"},{"product_id":"notifier-fcm-1-rel","title":"NOTIFIER FCM-1-REL Releasing Control Module, FlashScan","description":"\u003cp\u003eThe \u003cstrong\u003eNOTIFIER FCM-1-REL\u003c\/strong\u003e Releasing Control Module is designed for fire suppression releasing applications in FlashScan® systems. Power to the release agent solenoid(s) runs through the module for full-time monitoring and supervision.\u003c\/p\u003e\n\u003cp\u003eIt uses a redundant protocol: the module must be armed with a pair of signals, then enters a 3-second window awaiting a pair of confirmation signals, otherwise it automatically resets. It supervises wiring to the load and reports NORMAL, OPEN or SHORT CIRCUIT to the panel. It can drive one 24 VDC solenoid or up to two 12 VDC solenoids in series.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRedundant arm\/confirm protocol for added protection\u003c\/li\u003e\n\u003cli\u003eConfigurable for Class A or Class B operation; two pairs of output terminations for fault-tolerant wiring\u003c\/li\u003e\n\u003cli\u003eExternal supply voltage monitoring\u003c\/li\u003e\n\u003cli\u003ePanel-controlled status LED; rotary address switches; analog communications\u003c\/li\u003e\n\u003cli\u003eLow standby current; SEMS screws for easier wiring\u003c\/li\u003e\n\u003cli\u003eMounts in a standard 4\" junction box (optional SMB500 surface backbox; CB500 barrier required by UL when mixing power-limited and non-power-limited wiring)\u003c\/li\u003e\n\u003cli\u003eManufacturer: Notifier | Part Number: FCM-1-REL | Condition: New\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eRequired for new FlashScan-mode releasing applications with NFS2-3030 (v14.0+), NFS2-640 (v12.0+) and NFS-320 (v12.0+). Use FCM-1 for releasing on NFS-640, NFS-3030 and all CLIP-mode panels. See Notifier compatibility document PN 15378 for compatible solenoids. Always verify compatibility with your system and local code requirements before ordering.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Notifier (Honeywell)\u003cbr\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e FCM-1-REL (ULC version: FCM-1-RELA)\u003cbr\u003e\n\u003cstrong\u003eOperating Voltage:\u003c\/strong\u003e 15 to 32 VDC\u003cbr\u003e\n\u003cstrong\u003eSLC Average Operating Current:\u003c\/strong\u003e 700 µA max @ 24 VDC; max activation current 9.0 mA (LED on)\u003cbr\u003e\n\u003cstrong\u003eExternal Supply:\u003c\/strong\u003e 24 VDC nominal; standby 6.4 mA; activation 10 mA; max line loss 2.3 VDC; min 18 VDC at solenoid\u003cbr\u003e\n\u003cstrong\u003eSolenoid Circuit:\u003c\/strong\u003e supervisory 3.3 V \/ 30 mA; maximum activation current 2 A\u003cbr\u003e\n\u003cstrong\u003eTemperature:\u003c\/strong\u003e 14°F to 140°F (-10°C to 60°C)\u003cbr\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 10% to 95% RH, non-condensing\u003cbr\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 4.275\" W × 4.675\" H × 1.400\" D\u003cbr\u003e\n\u003cstrong\u003eShipping Weight:\u003c\/strong\u003e 5.5 oz (156 g)\u003cbr\u003e\n\u003cstrong\u003eListings:\u003c\/strong\u003e UL S635; ULC (FCM-1-RELA); FM Approved; CSFM 7300-0028:249\u003c\/p\u003e","brand":"NOTIFIER","offers":[{"title":"Default Title","offer_id":54082224587059,"sku":"FCM-1-REL","price":204.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1000\/9785\/1699\/files\/notifier-fcm-1-rel-plena-v2.png?v=1795214417"},{"product_id":"notifier-fdrm-1","title":"NOTIFIER FDRM-1 FlashScan Dual Relay \/ Dual Monitor Module","description":"\u003cp\u003eThe \u003cstrong\u003eNOTIFIER FDRM-1\u003c\/strong\u003e is a FlashScan® multi output-input module for Notifier ONYX® and CLIP series fire alarm control panels. Intended for intelligent two-wire SLC loops, it combines two individual relay control modules and two Class B monitor modules in one device.\u003c\/p\u003e\n\u003cp\u003eEach relay output is intended for Form C switching applications that do not require wiring supervision for the load circuit; each monitor input interfaces the panel with one or more normally open contact-type devices. Each relay output has its own green LED, and each monitored input has its own bi-color LED controlled by the panel.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTwo Form C relay outputs and two Class B (Style B) monitor inputs in one module\u003c\/li\u003e\n\u003cli\u003ePowered directly by the SLC loop, no external power required\u003c\/li\u003e\n\u003cli\u003eRotary decimal addressing (1–99 on CLIP systems, 1–159 on FlashScan systems); uses up to four addresses\u003c\/li\u003e\n\u003cli\u003eDIP switches can disable relay output #2 or monitored input #2 to free addresses\u003c\/li\u003e\n\u003cli\u003eAddresses can be viewed and changed without electronic programmers\u003c\/li\u003e\n\u003cli\u003eIntegral LEDs flash green in normal operation (programmable) and latch steady red for alarm\u003c\/li\u003e\n\u003cli\u003eAddressable-analog communication; sleek low-profile design\u003c\/li\u003e\n\u003cli\u003eMounts to a standard 4\" square, 2-1\/8\" deep junction box; surface-mount box available\u003c\/li\u003e\n\u003cli\u003eManufacturer: Notifier | Part Number: FDRM-1 | Condition: New\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNote: inputs and outputs provide Class B (Style B) circuits only; Class A (Style D) is not supported. Always verify compatibility with your system and local code requirements before ordering.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Notifier (Honeywell)\u003cbr\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e FDRM-1 (FDRM-1A is the ULC model)\u003cbr\u003e\n\u003cstrong\u003eNormal Operating Voltage:\u003c\/strong\u003e 15 to 32 VDC\u003cbr\u003e\n\u003cstrong\u003eMaximum Current Draw:\u003c\/strong\u003e 24 mA (4 LEDs on)\u003cbr\u003e\n\u003cstrong\u003eRelay Contact Ratings:\u003c\/strong\u003e 3 A @ 30 VDC resistive (non-coded); 2 A @ 30 VDC resistive (coded); 2 A @ 25 VAC PF 0.35; 0.46 A @ 30 VDC L\/R 20 ms; 0.7 A @ 70.7 VAC PF 0.35; 0.9 A @ 125 VDC resistive; 0.5 A @ 125 VAC PF 0.75; 0.3 A @ 125 VAC PF 0.35\u003cbr\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 32°F to 120°F (0°C to 49°C)\u003cbr\u003e\n\u003cstrong\u003eRelative Humidity:\u003c\/strong\u003e 10% to 93% non-condensing\u003cbr\u003e\n\u003cstrong\u003eSize:\u003c\/strong\u003e 4.675\" H × 4.275\" W × 1.4\" D\u003cbr\u003e\n\u003cstrong\u003eShipping Weight:\u003c\/strong\u003e 6.3 oz (178.6 g)\u003cbr\u003e\n\u003cstrong\u003eListings:\u003c\/strong\u003e UL\/ULC S635; CSFM 7300-0028:0219\u003c\/p\u003e","brand":"NOTIFIER","offers":[{"title":"Default Title","offer_id":54082224849203,"sku":"FDRM-1","price":299.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1000\/9785\/1699\/files\/notifier-fdrm-1-plena-v2.png?v=1795214417"},{"product_id":"notifier-iso-x","title":"NOTIFIER ISO-X Fault Isolator Module for SLC Loops","description":"\u003cp\u003eThe \u003cstrong\u003eNOTIFIER ISO-X\u003c\/strong\u003e Fault Isolator Module is used with Notifier ONYX® and CLIP series fire alarm control panels to protect the system against wire-to-wire short circuits on the SLC loops.\u003c\/p\u003e\n\u003cp\u003eIsolators are spaced between groups of devices on a loop. If a short occurs between two isolators, both switch to an open-circuit state and isolate that section while the rest of the loop keeps operating. The module automatically restores the shorted portion when the short is removed. In Style 4 loops it is generally used at each T-tap branch.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePowered directly by the SLC loop, no external power and no address required\u003c\/li\u003e\n\u003cli\u003eOpens the SLC automatically on detection of a short (line voltage below 4 V) and resets automatically when corrected\u003c\/li\u003e\n\u003cli\u003eSupports Style 4, 6 or 7 wiring\u003c\/li\u003e\n\u003cli\u003eIntegral yellow LED pulses in normal condition, steady when a short is detected; wide viewing angle\u003c\/li\u003e\n\u003cli\u003eHigh noise (EMF\/RFI) immunity; SEMS screws with clamping plates\u003c\/li\u003e\n\u003cli\u003eMounts on a standard 4\" square junction box at least 2-1\/8\" deep; surface-mount box optional\u003c\/li\u003e\n\u003cli\u003eMaximum 25 devices between isolators (B224RB relay base counts as 2.5 devices)\u003c\/li\u003e\n\u003cli\u003eManufacturer: Notifier | Part Number: ISO-X | Condition: New\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAlways verify compatibility with your system and local code requirements before ordering.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Notifier (Honeywell)\u003cbr\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e ISO-X (ULC version: ISO-XA)\u003cbr\u003e\n\u003cstrong\u003eOperating Voltage:\u003c\/strong\u003e 15 to 32 VDC (peak)\u003cbr\u003e\n\u003cstrong\u003eStandby Current:\u003c\/strong\u003e 450 µA (not isolating)\u003cbr\u003e\n\u003cstrong\u003eMaximum Current Draw:\u003c\/strong\u003e 17 mA (in isolation, LED latched)\u003cbr\u003e\n\u003cstrong\u003eTemperature:\u003c\/strong\u003e 32°F to 120°F (0°C to 49°C)\u003cbr\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 10% to 93% RH, non-condensing\u003cbr\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 4.5\" H × 4.5\" W × 0.25\" D\u003cbr\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 5 oz (150 g)\u003cbr\u003e\n\u003cstrong\u003eListings:\u003c\/strong\u003e UL S635; ULC S635 (ISO-XA); FM Approved; CSFM 7165-0028:0214, 7165-0028:0224 (see data sheet for full list)\u003c\/p\u003e","brand":"NOTIFIER","offers":[{"title":"Default Title","offer_id":54082226258227,"sku":"ISO-X","price":73.15,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1000\/9785\/1699\/files\/notifier-iso-x-plena-v2.png?v=1795214418"},{"product_id":"notifier-mr-101-cr","title":"NOTIFIER MR-101\/C\/R Multi-Voltage Control Relay, SPDT 10 A, Red Enclosure","description":"\u003cp\u003eThe \u003cstrong\u003eNOTIFIER MR-101\/C\/R\u003c\/strong\u003e is a single SPDT multi-voltage control relay with LED mounted in an enclosure with a red cover (Air Products MR-100 series). The relay may be energized from 24 VDC, 24 VAC, 115 VAC or 230 VAC by wiring to the appropriate input terminals, making it ideal for local status contacts, remote control of electrical loads and general switching in fire alarm, HVAC and building systems.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSingle SPDT relay, 10 A resistive contacts\u003c\/li\u003e\n\u003cli\u003eEnergized by 24 VDC, 24 VAC, 115 VAC or 230 VAC\u003c\/li\u003e\n\u003cli\u003eRed LED illuminates when the coil is energized\u003c\/li\u003e\n\u003cli\u003eMounted in an enclosure with red cover and LED viewing port; 1\/2 in. conduit knockouts\u003c\/li\u003e\n\u003cli\u003eUL recognized relays rated for 10,000,000 mechanical operations; UL listed as control unit accessory (\/C versions)\u003c\/li\u003e\n\u003cli\u003eFor continuous duty use\u003c\/li\u003e\n\u003cli\u003eManufacturer: Notifier \/ Air Products | Part Number: MR-101\/CR | Condition: New\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAlways verify compatibility with your system and local code requirements before ordering.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Air Products and Controls (for Notifier \/ Honeywell)\u003cbr\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e MR-101\/CR\u003cbr\u003e\n\u003cstrong\u003eCoil Current:\u003c\/strong\u003e 15 mA @ 24 VDC; 30 mA @ 24 VAC; 20 mA @ 115 VAC; 20 mA @ 230 VAC\u003cbr\u003e\n\u003cstrong\u003eContacts:\u003c\/strong\u003e SPDT\u003cbr\u003e\n\u003cstrong\u003eContact Rating:\u003c\/strong\u003e 10 A res. @ 115 VAC; 7 A res. @ 230 VAC; 7 A res. @ 28 VAC\u003cbr\u003e\n\u003cstrong\u003eEnclosure Dimensions (MR-101\/C):\u003c\/strong\u003e 5.125 in. H × 3.125 in. W × 2.5 in. D\u003cbr\u003e\n\u003cstrong\u003eEnclosure:\u003c\/strong\u003e 18 ga. CRS backbox; ABS-94VO cover (red on \/C\/R)\u003c\/p\u003e","brand":"NOTIFIER","offers":[{"title":"Default Title","offer_id":54082226815283,"sku":"MR-101\/CR","price":34.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1000\/9785\/1699\/files\/notifier-mr-101-cr-plena-v2.png?v=1795214418"},{"product_id":"notifier-pam-4","title":"NOTIFIER PAM-4 Multi-Voltage Encapsulated Relay, 9-40 VDC, SPDT Form C, Flying Leads","description":"\u003cp\u003eThe \u003cstrong\u003eNOTIFIER PAM-4\u003c\/strong\u003e is an encapsulated multi-voltage relay module with flying leads (manufactured by Space Age Electronics, SSU-PAM-4). It can be energized across a wide input range from 9 VDC to 40 VDC with a constant 15 mA operating current, ideal for remote relay control or status feedback in fire alarm, HVAC, security and building automation systems.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWide coil range: 9 to 40 VDC, 15 mA constant operating current\u003c\/li\u003e\n\u003cli\u003eOne SPDT dry Form C contact\u003c\/li\u003e\n\u003cli\u003ePolarity sensitive, diode-protected input\u003c\/li\u003e\n\u003cli\u003e100% potted (sealed) construction with 12 in. \/ 18 AWG flying leads; wire-nuts provided\u003c\/li\u003e\n\u003cli\u003ePre-drilled mounting hole with self-tapping screw and double-sided tape provided\u003c\/li\u003e\n\u003cli\u003eManufacturer: Notifier | Part Number: PAM-4 | Condition: New\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAlways verify compatibility with your system and local code requirements before ordering.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Notifier (Honeywell)\u003cbr\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e PAM-4\u003cbr\u003e\n\u003cstrong\u003eCoil Voltage:\u003c\/strong\u003e 9 to 40 VDC\u003cbr\u003e\n\u003cstrong\u003eCurrent:\u003c\/strong\u003e 15 mA @ 24 VDC\u003cbr\u003e\n\u003cstrong\u003eContacts:\u003c\/strong\u003e (1) SPDT dry Form C\u003cbr\u003e\n\u003cstrong\u003eContact Ratings:\u003c\/strong\u003e 7 A @ 24 VDC; 10 A @ 120 VAC\u003cbr\u003e\n\u003cstrong\u003eLED:\u003c\/strong\u003e No\u003cbr\u003e\n\u003cstrong\u003eAmbient Temperature:\u003c\/strong\u003e 32°F to 120°F (0°C to 49°C)\u003cbr\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 1.50\" H × 1.00\" W × 0.90\" D\u003cbr\u003e\n\u003cstrong\u003eListings:\u003c\/strong\u003e UL; CSFM 7300-1004:101; MEA 73-92-E Vol. 21\u003c\/p\u003e","brand":"NOTIFIER","offers":[{"title":"Default Title","offer_id":54082229600563,"sku":"PAM-4","price":17.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1000\/9785\/1699\/files\/notifier-pam-4-plena-v2.png?v=1795214544"},{"product_id":"simplex-4005-9807","title":"SIMPLEX 4005-9807 Power Distribution Module for 4005 Fire Alarm Panel","description":"\u003cp\u003eThe \u003cstrong\u003eSIMPLEX 4005-9807\u003c\/strong\u003e is a power distribution module for the legacy Simplex 4005 series fire alarm control panel, used for replacement or expansion in existing 4005 systems.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePower distribution module for Simplex 4005 series fire alarm control panels\u003c\/li\u003e\n\u003cli\u003eGenuine Simplex part for service and replacement in existing systems\u003c\/li\u003e\n\u003cli\u003eManufacturer: Simplex | Part Number: 4005-9807 | Condition: New\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eLegacy part: confirm the part number against the module installed in your panel before ordering. Always verify compatibility with your system and local code requirements before ordering.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Simplex (Johnson Controls)\u003cbr\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e 4005-9807\u003cbr\u003e\n\u003cstrong\u003eUsed With:\u003c\/strong\u003e Simplex 4005 series fire alarm control panel\u003c\/p\u003e","brand":"SIMPLEX","offers":[{"title":"Default Title","offer_id":54082236580147,"sku":"4005-9807","price":94.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1000\/9785\/1699\/files\/simplex-4005-9807-plena-v2.png?v=1795214547"},{"product_id":"simplex-4007-9802","title":"SIMPLEX 4007-9802 25 VDC Regulator Module for 4007ES, 2 A","description":"\u003cp\u003eThe \u003cstrong\u003eSIMPLEX 4007-9802\u003c\/strong\u003e is a 25 VDC Regulator Module for the Simplex 4007ES hybrid fire detection and control unit. It provides up to 2 A of regulated output to power Zone\/Relay modules connected to initiating devices requiring a nominal 25 VDC.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRegulated 25 VDC output, 2 A maximum\u003c\/li\u003e\n\u003cli\u003ePowers 4007ES Zone\/Relay modules connected to initiating devices requiring nominal 25 VDC\u003c\/li\u003e\n\u003cli\u003eField-installed optional module for the 4007ES\u003c\/li\u003e\n\u003cli\u003eManufacturer: Simplex | Part Number: 4007-9802 | Condition: New\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eRefer to Simplex technical publication 579-832 (2-Wire Detector Compatibility Chart) for application details. Always verify compatibility with your system and local code requirements before ordering.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Simplex (Johnson Controls)\u003cbr\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e 4007-9802\u003cbr\u003e\n\u003cstrong\u003eOutput:\u003c\/strong\u003e 25 VDC regulated, 2 A maximum\u003cbr\u003e\n\u003cstrong\u003eCurrent (with 1 module):\u003c\/strong\u003e Supervisory 190 mA; Alarm 445 mA\u003cbr\u003e\n\u003cstrong\u003eUsed With:\u003c\/strong\u003e 4007ES Fire Detection and Control Unit\u003c\/p\u003e","brand":"SIMPLEX","offers":[{"title":"Default Title","offer_id":54082236678451,"sku":"4007-9802","price":419.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1000\/9785\/1699\/files\/simplex-4007-9802-plena-v2.png?v=1795214547"},{"product_id":"simplex-4090-9001","title":"SIMPLEX 4090-9001 Individual Addressable Module (IAM)","description":"\u003cp\u003eThe \u003cstrong\u003eSimplex 4090-9001\u003c\/strong\u003e is an Individual Addressable Module (IAM). It monitors normally open dry contact inputs. Specifically, it brings non-addressable contact devices onto a Simplex IDNet or MAPNET II addressable loop.\u003c\/p\u003e\n\u003cp\u003eFirst, the module receives both power and data from a single two-wire IDNet or MAPNET II circuit. Then, it supervises the contact wiring out to an end-of-line resistor. As a result, the panel sees the exact device that changed state — not just a zone fault.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMonitors normally open, dry contact inputs\u003c\/li\u003e\n\u003cli\u003ePowered and supervised over a single IDNet or MAPNET II pair\u003c\/li\u003e\n\u003cli\u003eOne IDNet\/MAPNET address per module\u003c\/li\u003e\n\u003cli\u003eClass B supervised contact wiring\u003c\/li\u003e\n\u003cli\u003eUp to 500 ft (152 m) from IAM to end-of-line resistor\u003c\/li\u003e\n\u003cli\u003eUp to 400 ft when used with 2081-9044 overvoltage protectors\u003c\/li\u003e\n\u003cli\u003eVisible LED — flashes for communications, steady on alarm\u003c\/li\u003e\n\u003cli\u003eScrew terminals; thermoplastic enclosure minimizes dust ingress\u003c\/li\u003e\n\u003cli\u003eMounts in a standard single-gang electrical box\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatible Control Panels\u003c\/h3\u003e\n\u003cp\u003eFor IDNet communications:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSimplex 4008, 4010, 4010ES, 4100U, and 4100ES\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor MAPNET II communications:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSimplex 4100, 4100U, 4100ES, 4120, 4020\u003c\/li\u003e\n\u003cli\u003eSimplex 2120 Communicating Device Transponders (CDTs)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SIMPLEX","offers":[{"title":"Default Title","offer_id":54082236809523,"sku":"4090-9001","price":28.95,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1000\/9785\/1699\/files\/simplex-4090-9001-plena-v2.png?v=1795214545"},{"product_id":"simplex-4090-9002","title":"SIMPLEX 4090-9002 Individual Addressable Module","description":"\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cb\u003eSimplex 4090-9002\u003c\/b\u003e\u003cspan\u003e is a compact Relay Individual Addressable Module (IAM) designed to deliver precise auxiliary control via an addressable IDNet communications channel. Providing a single Form C (SPDT) dry contact output, it enables compatible Simplex fire alarm control panels to automate critical emergency functions—such as HVAC shutdown, elevator capture, damper operation, and fan control. Because it draws both data and operating power directly from the IDNet loop, installation wiring is significantly streamlined. Built to fit standard 4-inch square electrical boxes, the sealed module features an integrated status LED for fast diagnostics, reports real-time relay state to the panel, and automatically defaults to an OFF state during power loss or communication failure for fail-safe reliability. \u003c\/span\u003e\u003c\/p\u003e","brand":"SIMPLEX","offers":[{"title":"Default Title","offer_id":54082236973363,"sku":"4090-9002","price":56.99,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1000\/9785\/1699\/files\/simplex-4090-9002-plena-v2.jpg?v=1795214545"},{"product_id":"simplex-4090-9051","title":"SIMPLEX 4090-9051 Addressable Relay Module","description":"\u003cp class=\"p1\"\u003e\u003cb\u003eSimplex 4090-9051 Addressable Control Relay Module\u003c\/b\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"p3\"\u003eThe Simplex 4090-9051 is an addressable control relay module designed to provide efficient control and monitoring of auxiliary fire alarm system functions. This compact, high-performance module seamlessly integrates with Simplex fire alarm panels, allowing for precise activation of external devices such as door releases, fans, or notification appliances.\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e\u003cb\u003eKey Features:\u003c\/b\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"p4\"\u003e\u003cspan class=\"Apple-tab-span\"\u003e\u003c\/span\u003e•\u003cspan class=\"Apple-tab-span\"\u003e \u003c\/span\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eAddressable communication\u003c\/b\u003e\u003c\/span\u003e – Provides reliable status reporting and activation tracking.\u003c\/p\u003e\n\u003cp class=\"p4\"\u003e\u003cspan class=\"Apple-tab-span\"\u003e\u003c\/span\u003e•\u003cspan class=\"Apple-tab-span\"\u003e \u003c\/span\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eCompact design\u003c\/b\u003e\u003c\/span\u003e – Small footprint allows for easy installation in various locations.\u003c\/p\u003e\n\u003cp class=\"p4\"\u003e\u003cspan class=\"Apple-tab-span\"\u003e\u003c\/span\u003e•\u003cspan class=\"Apple-tab-span\"\u003e \u003c\/span\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eRemote-controlled operation\u003c\/b\u003e\u003c\/span\u003e – Enables activation of external devices for enhanced fire safety.\u003c\/p\u003e\n\u003cp class=\"p4\"\u003e\u003cspan class=\"Apple-tab-span\"\u003e\u003c\/span\u003e•\u003cspan class=\"Apple-tab-span\"\u003e \u003c\/span\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eLED status indicator\u003c\/b\u003e\u003c\/span\u003e – Displays communication and operational status for quick troubleshooting.\u003c\/p\u003e\n\u003cp class=\"p4\"\u003e\u003cspan class=\"Apple-tab-span\"\u003e\u003c\/span\u003e•\u003cspan class=\"Apple-tab-span\"\u003e \u003c\/span\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eUL-listed for compliance\u003c\/b\u003e\u003c\/span\u003e – Meets fire protection standards for reliable system integration.\u003c\/p\u003e","brand":"SIMPLEX","offers":[{"title":"Default Title","offer_id":54082237071667,"sku":"4090-9051","price":39.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1000\/9785\/1699\/files\/simplex-4090-9051-plena-v2.png?v=1795214545"},{"product_id":"simplex-4090-9116","title":"SIMPLEX 4090-9116 Addressable IDnet Isolator Module","description":"\u003cp\u003eThe \u003cstrong\u003eSimplex 4090-9116\u003c\/strong\u003e is the addressable IDNet communications isolator for short-circuit protection on addressable loops. First, it isolates a fault automatically when a short circuit occurs. In addition, the unit reports the isolation state to the host panel. Therefore, the 4090-9116 keeps the rest of the loop online during a single-point failure.\u003c\/p\u003e\n\u003ch3\u003eDual-Port, Bi-Directional Isolation\u003c\/h3\u003e\n\u003cp\u003eThe 4090-9116 has two communication ports. Specifically, either port can serve as the input or the output. As a result, the device drops into the loop without strict polarity wiring. Furthermore, the isolation activates automatically on a detected short circuit. Operators can also trigger isolation manually from the panel for troubleshooting.\u003c\/p\u003e\n\u003ch3\u003ePanel Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe isolator works with Simplex 4007ES, 4008, 4010ES, 4100ES, and 4100U panels. However, the supported channels include IDNet, IDNet+, IDNet 1+, IDNet 2, and IDNet 2+2 outputs. Also, the device is line-powered from the addressable loop itself.\u003c\/p\u003e\n\u003ch3\u003eOperating Environment\u003c\/h3\u003e\n\u003cp\u003eThe 4090-9116 operates between 32 °F (0 °C) and 120 °F (49 °C). Then, relative humidity may reach 93% non-condensing at 90 °F (32 °C). Therefore, the isolator suits typical indoor commercial environments without special enclosures.\u003c\/p\u003e","brand":"SIMPLEX","offers":[{"title":"Default Title","offer_id":54082237202739,"sku":"4090-9116","price":49.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1000\/9785\/1699\/files\/simplex-4090-9116-plena-v2.png?v=1795214545"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1000\/9785\/1699\/collections\/plena-collection-modules-relays.jpg?v=1795210411","url":"https:\/\/plenasupply.com\/collections\/modules-relays.oembed","provider":"Plena Supply","version":"1.0","type":"link"}