{"product_id":"notifier-b200s-lf-iv","title":"NOTIFIER B200S-LF-IV Intelligent Low-Frequency 520 Hz Sounder Base, Ivory","description":"\u003cp\u003eThe \u003cstrong\u003eNOTIFIER B200S-LF-IV\u003c\/strong\u003e is an ivory, intelligent, programmable low-frequency sounder base. It produces a fundamental frequency of 520 Hz ±10% with a square wave or its equivalent, designed to meet the NFPA 72 requirement (effective January 1, 2014) for audible appliances in sleeping areas. Studies have shown that low-frequency tones around 520 Hz are more effective at waking sleeping occupants.\u003c\/p\u003e\n\u003cp\u003eThe B200S-LF adopts the same address as the detector installed in it, and the panel can command each sounder — or a group of sounders — to activate. It supports ANSI Temporal 3 for fire, Temporal 4 for CO (with compatible CO detectors), continuous, March Time and custom tones, and recognizes the System Sensor synchronization protocol when connected to a compatible power supply or NAC output. In addition to the SLC, the base requires 24 VDC constant power or a NAC circuit, depending on the panel and intended use.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e520 Hz low-frequency square-wave tone for sleeping areas per NFPA 72\u003c\/li\u003e\n\u003cli\u003eProgrammable high or low volume\u003c\/li\u003e\n\u003cli\u003eANSI Temporal 3, Temporal 4, continuous, March Time and custom tone patterns\u003c\/li\u003e\n\u003cli\u003eUses FlashScan® protocol; shares the address of the installed detector\u003c\/li\u003e\n\u003cli\u003eSynchronizes with System Sensor notification appliances as part of the general evacuation signal\u003c\/li\u003e\n\u003cli\u003eIsolated 24 V constant\/NAC power and communication connections\u003c\/li\u003e\n\u003cli\u003eMeets UL 268 and UL 464 (Temporal 4 meets UL 268 and UL 2075)\u003c\/li\u003e\n\u003cli\u003eIvory; white version is B200S-LF-WH\u003c\/li\u003e\n\u003cli\u003eManufacturer: Notifier | Part Number: B200S-LF-IV | Condition: New\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDetector head sold separately. Not compatible with remote-test-capable 200 series detectors. Always verify compatibility with your system and local code requirements before ordering.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Notifier (Honeywell) \/ System Sensor\u003cbr\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e B200S-LF-IV\u003cbr\u003e\n\u003cstrong\u003eBase Diameter:\u003c\/strong\u003e 6.875\" (17.46 cm)\u003cbr\u003e\n\u003cstrong\u003eBase Height (less sensor):\u003c\/strong\u003e 2.0\" (5.08 cm)\u003cbr\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.6 lb (272 g)\u003cbr\u003e\n\u003cstrong\u003eExternal Supply Voltage:\u003c\/strong\u003e 16 to 33 VDC (VFWR)\u003cbr\u003e\n\u003cstrong\u003eStandby Current:\u003c\/strong\u003e 550 µA maximum\u003cbr\u003e\n\u003cstrong\u003eAlarm Current, High Volume:\u003c\/strong\u003e 70 mA max @ 33 VDC; 90 mA max @ 24 VDC; 140 mA max @ 16 VDC\u003cbr\u003e\n\u003cstrong\u003eAlarm Current, Low Volume:\u003c\/strong\u003e 15 mA max @ 33 VDC; 20 mA max @ 24 VDC; 25 mA max @ 16 VDC\u003cbr\u003e\n\u003cstrong\u003eSLC Operating Voltage:\u003c\/strong\u003e 15 to 32 VDC\u003cbr\u003e\n\u003cstrong\u003eSound Output:\u003c\/strong\u003e greater than 85 dBA (high) \/ 75 dBA (low) minimum, UL reverberant room at 10 ft, 24 V\u003cbr\u003e\n\u003cstrong\u003eOperating Humidity:\u003c\/strong\u003e 10% to 93% RH non-condensing\u003c\/p\u003e","brand":"NOTIFIER","offers":[{"title":"Default Title","offer_id":54082221867315,"sku":"B200S-LF-IV","price":68.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1000\/9785\/1699\/files\/notifier-b200s-lf-iv-plena-v2.png?v=1795214417","url":"https:\/\/plenasupply.com\/products\/notifier-b200s-lf-iv","provider":"Plena Supply","version":"1.0","type":"link"}