{"product_id":"notifier-fsp-951-addressable-photoelectric-smoke-detector","title":"Notifier FSP-951 Intelligent Addressable Photoelectric Smoke Detector","description":"\u003cp class=\"isSelectedEnd\"\u003eThe \u003cstrong\u003eNotifier FSP-951\u003c\/strong\u003e is a commercial addressable smoke detector designed for compatible Notifier addressable fire alarm systems. It features an enhanced smoke sensing chamber engineered to detect smoke from a wide range of combustion sources while providing dependable performance and reduced nuisance alarms.\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003eThe detector incorporates programmable sensitivity, rotary decimal addressing, dual status LEDs, and continuous communication with the fire alarm control panel for alarm reporting and maintenance supervision. Its low-profile plug-in design simplifies installation and servicing. This product is intended exclusively for commercial fire alarm installations.\u003c\/p\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch3\u003eProduct Functions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDetects airborne smoke\u003c\/li\u003e\n\u003cli\u003eReports alarm conditions to the fire alarm control panel\u003c\/li\u003e\n\u003cli\u003eProgrammable detector sensitivity\u003c\/li\u003e\n\u003cli\u003eContinuous detector supervision\u003c\/li\u003e\n\u003cli\u003eAutomatic maintenance monitoring\u003c\/li\u003e\n\u003cli\u003eIndividual device identification\u003c\/li\u003e\n\u003cli\u003eDual LED status indication\u003c\/li\u003e\n\u003cli\u003eSupports magnetic functional testing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch3\u003eElectrical \u0026amp; System Information\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003eThe FSP-951 operates on compatible Notifier FlashScan® addressable signaling line circuits (SLC) with an operating voltage range of 15–32 VDC. The detector communicates continuously with the fire alarm control panel, allowing programmable sensitivity, maintenance alerts, and precise device identification.\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003eRotary decimal address switches provide simple field addressing, while the plug-in detector head installs on compatible Notifier detector bases.\u003c\/p\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCommercial\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eaddressable smoke detector\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eEnhanced smoke sensing chamber\u003c\/li\u003e\n\u003cli\u003eProgrammable sensitivity\u003c\/li\u003e\n\u003cli\u003eRotary decimal addressing\u003c\/li\u003e\n\u003cli\u003eDual LEDs with 360° visibility\u003c\/li\u003e\n\u003cli\u003ePlug-in detector head\u003c\/li\u003e\n\u003cli\u003eLow-profile housing\u003c\/li\u003e\n\u003cli\u003eMagnetic test capability\u003c\/li\u003e\n\u003cli\u003eAutomatic maintenance indication\u003c\/li\u003e\n\u003cli\u003eRemote LED annunciator support\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch3\u003eMounting \u0026amp; Design\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003eThe FSP-951 installs on compatible B300-6 Series, B501 Series, B210LP, B224RB, B224BI, and B200S detector bases. Its plug-in construction allows quick installation, inspection, cleaning, testing, and replacement without disturbing field wiring.\u003c\/p\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch3\u003eProtection \u0026amp; Applications\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003eSuitable for:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOffice Buildings\u003c\/li\u003e\n\u003cli\u003eSchools\u003c\/li\u003e\n\u003cli\u003eHospitals\u003c\/li\u003e\n\u003cli\u003eHotels\u003c\/li\u003e\n\u003cli\u003eRetail Facilities\u003c\/li\u003e\n\u003cli\u003eWarehouses\u003c\/li\u003e\n\u003cli\u003eGovernment Buildings\u003c\/li\u003e\n\u003cli\u003eIndustrial Facilities\u003c\/li\u003e\n\u003cli\u003eCommercial Properties\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003eCompatible with:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNotifier ONYX Fire Alarm Control Panels\u003c\/li\u003e\n\u003cli\u003eFlashScan Addressable Signaling Line Circuits\u003c\/li\u003e\n\u003cli\u003eB300-6 Series Detector Bases\u003c\/li\u003e\n\u003cli\u003eB501 Series Detector Bases\u003c\/li\u003e\n\u003cli\u003eB210LP Detector Base\u003c\/li\u003e\n\u003cli\u003eB224RB Relay Base\u003c\/li\u003e\n\u003cli\u003eB224BI Isolator Base\u003c\/li\u003e\n\u003cli\u003eB200S Sounder Base\u003c\/li\u003e\n\u003cli\u003eRA400Z Remote LED Annunciator\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003eAlways verify compatibility with the installed fire alarm control panel, detector base, firmware version, and project requirements before installation.\u003c\/p\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNotifier\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003eParent Company:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHoneywell\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFSP-951\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAddressable Smoke Detector\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003eDetection Method:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePhotoelectric Smoke Sensing\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003eOperating Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e15–32 VDC Peak\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003eTypical Standby Current:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e200 µA @ 24 VDC\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003eMaximum Operating Current:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4.5 mA @ 24 VDC\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003eSensitivity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.5%–4.0% Obscuration per Foot (UL Applications)\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003eAddressing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRotary Decimal Switches\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003eStatus Indicators:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDual LEDs\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e32°F to 122°F (0°C to 50°C)\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003eOperating Humidity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e10%–93% RH Non-Condensing\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003eAir Velocity Rating:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0–4,000 ft\/min\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCompatible Notifier Detector Base Required\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003eHousing Color:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhite\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIndoor Commercial Fire Alarm Systems\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003eListings:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUL\/ULC Listed, FM Approved, and CSFM Listed (application dependent).\u003c\/p\u003e","brand":"NOTIFIER","offers":[{"title":"Default Title","offer_id":54014020976947,"sku":"FSP-951","price":66.96,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1000\/9785\/1699\/files\/NotifierFSP-951IntelligentAddressablePhotoelectricSmokeDetector1.webp?v=1788811624","url":"https:\/\/plenasupply.com\/products\/notifier-fsp-951-addressable-photoelectric-smoke-detector","provider":"Plena Supply","version":"1.0","type":"link"}